Monitoring the RF Gateway 1
Session Refresh
The RFGW-1 generates an input pid conflict alarm (Alarms/Events section) if any ES
or the PMT pid in an MPTS is the same as a pid already in use in the same MPTS.
Recall that it is the user's responsibility to ensure that the pids in an MPTS are
unique. To clear the pid conflict alarm it is necessary to not only resolve the input
pid conflict at the source e.g. the DCM but also to refresh the associated sessions as
seen in the following screen shots. Recall that the pid conflict is to be resolved before
refreshing the session.
Once input PID conflict is detected, the services that are involved in the conflict will
not be routed to the output.
Session Refresh Procedure
Find out the IP address of the MPTS with the conflict:
Verify that the MPTS displays the input pid conflict by viewing the input monitor
page:
Hunt for the output session with the pid conflict by searching through the output
monitor detail pages: