Cisco D9854 Installation And Configuration Manual page 93

Hide thumbs Also See for D9854:
Table of Contents

Advertisement

Menu Item
Description
Signal Lock Timer
Indicates the time, in seconds, the unit must wait
for a signal lock before declaring that the signal is
not usable and move on to the next search location
in the search path.
If the Profile is set to User, it displays the time set
by the local unit.
If the Profile is set to Uplink, it displays the time
set by the PNC uplink. But if the unit is not
connected to the uplink, the default value of the
unit is displayed.
Verify Timer
Indicates the time, in seconds, the unit must wait
for the PAT table to verify the signal has a valid
transport.
If the Profile is set to User, it displays the time set
by the local unit.
If the Profile is set to Uplink, it displays the time
set by the PNC uplink. But if the unit is not
connected to the uplink, the default value of the
unit is displayed.
Backup Channel Status
Menu Item
Description
PE
Displays the program entry.
Backup Channel
Displays the channel number assigned to the
selected backup transport.
Transport #
Displays the backup transport number for the
program entry selected.
Backup Transport Status
Menu Item
Description
Backup
Indicates the configured backup transport entry
number.
Input, NetId, Freq
For information on the tuning parameters, see
(GHz), SymRate,
Status Menu: TS Input (on page 59).
FEC, OrbPos, E/W,
Note: The RF input must be configured to match
Pol, Modulation,
the bandwidth of the backup parameters.
Rolloff, Config by
Status Menu
Parameters
5 to 255
10 to 255
Parameters
PE1 to PE16
1, 2, or 3
Parameters
1, 2, or 3
69