Chapter 6 Service and Maintenance
Alarm
Message
Type
LMI setup
Set
LMI setup
Clear
Param Storage
Set
Param Storage
Set
Param Storage
Set
Param Storage
Set
328
Message
Cause/Remedy
LMI SDRAM
Cause: Hardware
exhaust test failed
issue.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco Services if
the problem
persists.
LMI Video
SDRAM exhaust
test passed
DB NVS flushing
Cause: Hardware
ignored
issue.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco Services if
the problem
persists.
RAM flush to NVS
Cause: Hardware
failed
issue.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco Services if
the problem
persists.
DB Factory Reset
Cause: Standard
in progress
operation.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco Services if
the problem
persists.
DB Total Reset in
Cause: Standard
progress
operation.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco Services if
the problem
persists.
Description
Severity
DDR RAM on
Major
LMI bus not
working.
DDR RAM on
Major
LMI bus OK.
Non-volatile
Major
storage system
failed to update
fully.
Non-volatile
Major
storage system
failed to update
fully.
Non-volatile
Major
storage system
operation in
progress.
Non-volatile
Major
storage system
operation in
progress.
ID
22000
22000
23000
23000
23000
23000