Chapter 6 Service and Maintenance
Warning
Message
Type
Temperature
Set
Warning
Temperature
Clear
Warning
FPGA
Set
Temperature
Warning
FPGA
Clear
Temperature
Warning
VBI Data
Set
VBI Data
Clear
TDT timeout #
Set
350
Message
Cause/Remedy
Temperature
Cause: Room
over Warning
temperature too high, or
threshold
air flow is blocked.
Remedy: Check
openings on front and
rear panels for blockage.
Lower the room
temperature or improve
air flow to the device.
Temperature
normal
Temperature
Cause: Room
over Warning
temperature is too high,
threshold
or air flow is blocked.
Remedy: Check the
openings on front and
rear panels for blockage.
Lower the room
temperature or improve
air flow to the device.
Temperature
normal
2nd VBI PID
Cause: Uplink
attempt to write
configuration issue.
same line
Remedy: Contact uplink
to verify expected VBI
settings.
Line Collision
Cleared
TDT timed out
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
Description
Temperature is above
normal operating
range.
Temperature is within
the normal operating
range.
FPGA temperature is
above normal
operating range.
FPGA temperature is
within the normal
operating range.
Conflicting VBI data
on second VBI PID.
Time Date Table was
never received.
ID
44000
44000
45000
45000
49000
49000
50000