Display Power - HP FlexFabric 12900 series Command Reference Manual

Hide thumbs Also See for FlexFabric 12900 series:
Table of Contents

Advertisement

First notification at: 0.0
Latest notification at: 0.0
Total number of notifications sent: 0
[Enter severe low-memory state]
First notification at: 0.0
Latest notification at: 0.0
Total number of notifications sent: 0
[Back to severe low-memory state]
First notification at: 0.0
Latest notification at: 0.0
Total number of notifications sent: 0
[Enter critical low-memory state]
First notification at: 0.0
Latest notification at: 0.0
Total number of notifications sent: 0

display power

Use display power to display power supply information.
Syntax
In standalone mode:
display power [ power-id ]
In IRF mode:
display power [ chassis chassis-number [ power-id ] ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
chassis chassis-number: Specifies an IRF member device by its member ID. If you do not specify this
option, the command displays power supply information on all IRF member devices. (In IRF mode.)
power-id: Specifies a power supply by its ID. If you do not specify this option, the command displays
information about all power supplies.
Examples
# Display power supply information.
<Sysname> display power
PowerID State
1
Normal
2
Fault
3
Absent
4
Absent
5
Absent
Current(A)
Voltage(V)
10.40
54.00
--
--
--
--
--
--
--
--
Power(W)
561.60
--
--
--
--
213

Advertisement

Table of Contents
loading

Table of Contents