Display Resolution; Backlash; Maximum Error - Newport MM4006 Manual

8-axis motion controller/driver
Hide thumbs Also See for MM4006:
Table of Contents

Advertisement

MM4006
2.2.2.5
H O M E
2.2.2.6
H O M E
2.2.2.7
EDH0181En1020 — 03/03

Display Resolution

This menu modified axis position (digit number after decimal point). The con-
troller used this parameter to adjust exactly the mechanical displacement.
To change the Display Resolution, press the
keypad to enter a new value and then press
and return to the previous menu.
JOG
AXES
1
2
3
1/5
4
5
6
1 :
-
3
. 3 5
6
m
m
Axis Setup
2 :
1
2
. 3 4 5
2/6
D e g
3 :
2 . 3 4
5 6
m
m
7
8
9
4 :
U
n
c o n
n e c t
e d
3/7
S
e
l e c
t
a c t i o n
-
0
.
M A N U
A
L
M O V E
P R O G .
4/8
QUIT
NP — Set display resolution.

Backlash

This parameter represents the mechanical hysteresis of motion device. Use
good judgment when setting this parameter.
To change the backlash parameter, press the
keypad to enter a new value and then press
and return to the previous menu.
If you have been following the Axes Setup procedure from the beginning of
the section, pressing the
meter that was discussed. Exit the Axes Setup by pressing the
JOG
AXES
1
2
3
1/5
1 :
-
3
. 3 5
6
m
m
4
5
6
Axis Setup
2/6
2 :
1
2
. 3 4 5
D e g
2 . 3 4
5 6
m
m
3 :
7
8
9
4 :
U
n
c o n
n e c t
e d
3/7
S
e
l e c
t
a c t i o n
.
M A N U
A
L
M O V E
-
P R O G .
0
4/8
QUIT
BA — Set mechanical backlash.

Maximum Error

This parameter represents the maximum allowed following error. If, at any
time, the following error exceeds this value, the controller stops all
motions in progress and turns the motor power off. Use good judgment
when setting this parameter. A small value will cause premature fault and a
large value will not protect the system from a real problem.
To change the Maximum Error parameter, press the
numeric keypad to enter a new value and then press
setting and return to the previous menu.
If you have been following the Axes Setup procedure from the beginning of
the section, pressing the
meter that was discussed. Exit the Axes Setup by pressing the key.
MODIFY
UP
QUIT
YES
UP
MODIFY
UP
QUIT
YES
UP
2.20
key. Use the numeric
MODIFY
to confirm the setting
VALID
JOG
AXES
1
2
3
1/5
MODIFY
4
5
6
2/6
7
8
9
3/7
.
-
0
4/8
QUIT
key. Use the numeric
MODIFY
to accept the setting
VALID
key will bring you back to the first para-
JOG
AXES
1
2
3
1/5
MODIFY
4
5
6
2/6
7
8
9
3/7
.
-
0
4/8
QUIT
MODIFY
VALID
key will bring you back to the first para-
Local Mode
VALID
key.
QUIT
VALID
key. Use the
to accept the