<4-COLOR>
UNEVEN IMAGE
A. Typical Faulty Images
B. Troubleshooting Procedure
Step
Section
1
Toner
The Toner Cartridge of every
Cartridge
color is surely installed.
2
PH Unit
PH Unit is surely installed.
3
Uneven pitch occurs in 3.0
mm pitch.
4
Toner
There is any stain or breakage
Cartridge
on the Drive section of the
Toner Cartridge.
5
Toner
There is any stain, damage or
Cartridge
abrasion on the PC drum.
6
2nd Transfer
There is any stain, damage,
Roller
deformation or abrasion on the
2nd Transfer Roller.
7
Fusing Unit
There is any stain, damage,
deformation or abrasion on the
Roller and Drive section of the
Fusing Unit.
8
The problem has been
eliminated through the check
of step 7.
Troubleshooting
Downloaded from
www.Manualslib.com
4138fs4507c0
Check Item
Result
NO
Re-install it.
NO
Re-install it.
YES
Replace PH Unit Stopper.
(p.175)
YES
Clean/replace the Toner
Cartridge.
YES
Replace the Toner Cartridge.
(p.175)
YES
Replace the 2nd Transfer
Roller.
(p.169)
YES
Replace the Fusing unit.
(p.162)
NO
Replace the Transfer Belt.
(p.162)
manuals search engine
<MONOCOLOR> OR <4-COLOR>
IMAGE TROUBLES THAT APPEAR AT REGULAR INTERVALS
When an image trouble occurred at the certain pitch, some rollers at the printing
process or the paper conveying system in the engine have something wrong. Perform
efficient trouble shooting by checking the appropriate roller, based on circumferential
length (interval) for each roller listed in the following table.
Check as follows.
1.
Check the pitch (interval) of image troubles
2.
Refer to the following table to find out the appropriate roller.
3.
Check if the roller has foreign matters or damages at the point that matches
with the image trouble point.
Circumferential Length
94.20mm
50.24mm
Action
62.61mm
125.60mm
116.18mm
(751 ± 0.7mm)
Image quality problem
Roller
Unit to be Replaced
PC Drum
Photoconductor Unit
Developing Roller
2nd Transfer Roller
2nd Transfer Roller
Heating Roller
Fusing Unit
Pressure Roller
Transfer Belt
Transfer Belt Unit