3.5.3 Solution

<MONOCOLOR>
WHITE LINES IN SUB SCAN DIRECTION, WHITE BANDS IN SUB SCAN
DIRECTION, COLORED LINES COLORED BANDS IN SUB SCAN
DIRECTION
A. Typical Faulty Images
White lines in Sub
White bands in Sub
Scan Direction
Scan Direction
4036fs4021c0
B. Troubleshooting Procedure
Step
Section
1
Photoconductor
The surface of the PC
Unit
Drum is scratched.
2
Dirty on the outside.
3
Contact terminals make
good connection between
each PU and machine.
4
Developing bias contact
terminal makes good
connection.
5
PH Unit
The surface of the PH
Window is dirty.
6
The problem has been
eliminated through the
checks of steps up to 5.
Troubleshooting
Downloaded from
www.Manualslib.com
Colored lines in Sub
Colored bands in
Scan Direction
Sub Scan Direction
4036fs4022c0
4036fs4023c0
Check Item
Result
YES
Change Photoconductor Unit.
YES
Clean.
NO
Clean contact terminals.
NO
Clean contact terminal and
check terminal position.
YES
Clean with cleaning jig.
NO
Change Photoconductor Unit.
Change Transfer Belt.
(p.162)
Change PH Unit.
manuals search engine
<MONOCOLOR>
WHITE LINES IN MAIN SCAN DIRECTION, WHITE BANDS IN MAIN
SCAN DIRECTION, COLORED LINES IN MAIN SCAN DIRECTION,
COLORED BANDS IN MAIN SCAN DIRECTION
A. Typical Faulty Images
White lines in Main
Scan Direction
4036fs4025c0
4036fs4024c0
B. Troubleshooting Procedure
Step
Section
1
Photoconductor
Action
Unit
2
3
4
5
PH Unit
6
(p.175)
Image quality problem
White bands in Main
Colored lines in Main
Scan Direction
Scan Direction
4036fs4026c0
4036fs4027c0
Check Item
Result
The surface of the PC
YES
Change Photoconductor Unit.
Drum is scratched.
Dirty on the outside.
YES
Clean.
Contact terminals make
NO
Clean contact terminals.
good connection between
each PU and machine.
Developing bias contact
NO
Clean contact terminal and
terminal makes good
check terminal position.
connection.
The surface of the PH
YES
Clean with cleaning jig.
Window is dirty.
The problem has been
NO
Change Photoconductor Unit.
eliminated through the
checks of steps up to 5.
(p.162)
Revision D
Colored bands in
Main Scan
Direction
4036fs4028c0
Action
Change Transfer Belt.
Change PH Unit.
(p.175)
139