5.2.2 MP Tray Mechanical Adjustment
PURPOSE
Adjust the mounting location of the MP tray to operate the MP tray properly.
PROCEDURE
1.
Install the gear so that the protrusion of the gear [1] and the mark [3] on the rack
gear [2] are aligned in a straight line.
Place the MP tray to match the ▼ on the surface of the MP tray Unit with the
2.
center of the scale.
3.
After installing the base plate, check whether Paper Guide operates smoothly.