Alarm, error, and system messages
22.5 PLC and NC variables
Note
"Filter/Search" when inserting variables
The start value for "Filter/Search" of variables differs.
For example, to insert the variable $R[0], set "Filter/Search":
• The start value is 0, if you filter according to "System variables".
• The start value is 1, if you filter according to "All (no filter)". In this case, all signals are
Changing operands
Depending on the type of operand, you can increment or decrement the address by 1 place
at a time using the "Operand +" and "Operand -" softkeys.
Note
Axis names as index
For axis names, the softkeys "Operand +" and "Operand -" do not act as index, e.g. for
$AA_IM[X1].
22.5.2

Saving and loading screen forms

You have the option of saving the configurations of the variables made in the "NC/PLC
variables" window in a screen form that you reload again when required.
Editing screen forms
If you change a screen form that has been loaded, then this is marked using with * after the
screen form name.
The name of a screen form is kept in the display after switching-off.
684
displayed and shown in the OPI notation.
Examples
DB97.DBX2.5
Result: DB97.DBX2.6
$AA_IM[1]
Result: $AA_IM[2]
MB201
Result: MB200
/Channel/Parameter/R[u1,3]
Result: /Channel/Parameter/R[u1,2]
Operating Manual, 02/2012, 6FC5398-7CP40-3BA0