Easy Extend (828D only)
19.4 Commissioning Easy Extend
19.4
Commissioning Easy Extend
As a rule, the "Easy Extend" function has already been commissioned by the machine
manufacturer. If a first commissioning has not been performed or if, for example, function
tests are to be performed again (e.g. when retrofitting additional devices), this is possible at
any time.
The "Start-up" softkey has been declared as Manufacturer data class (M).
Procedure
650
1.
Select the "Parameter" operating area.
2.
Press the menu forward key and then the "Easy Extend" softkey.
3.
Press the "Start-up" softkey.
A new vertical softkey bar appears.
4.
Press the "Comm. start-up" softkey to start the commissioning.
Before starting, a complete data backup is generated which you can
then use in an emergency.
5.
Press the "Cancel" softkey if you want to abort the commissioning
prematurely.
6.
Press the "Restore" softkey to load the original data.
7.
Press the "Device function test" softkey to test the machine
manufacturer's intended function.
Operating Manual, 02/2012, 6FC5398-7CP40-3BA0
Milling