8.2.1 Configuration

Data acquisition by I/O elements can be configured selecting I/O menu in configurator
(refer to chapter 6.3.3.5.2).
Priority: Low – as a regular data; High – generated record are sent immediately to server;
Panic - generated record are sent immediately to server and simultaneously the same record as
SMS message;
High Level: High range of value input;
Low Level: Low Range of value input;
Averaging constant: (see detailed description in chapter 6.3.3.5.2)

8.2.2 Event generation

There are five record event generation type examples (I/O speed is taken as I/O value
example), please refer to Figures below.
1. On Zone Exit
Speed,
Km/h
100
20
0
- Event Generated / Record Saved
Figure 47 Event On Zone exit
3. On Both
Speed,
Km/h
100
20
0
- Event Generated / Record Saved
Figure 49 Event On both
High Level
Low Level
Time, t
High Level
Low Level
Time, t
5. Hysterisis
Speed,
Km/h
100
20
0
- Event Generated / Record Saved
Figure 51 Event on Hysteresis
2. On Zone Entrance
Speed,
Km/h
100
20
0
- Event Generated / Record Saved
Figure 48 Event On Zone entrance
4. Monitoring
Speed,
Km/h
100
20
0
- Event Generated / Record Saved
Figure 50 Monitoring
High Level
Low Level
Time, t
High Level
Low Level
Time, t
High Level
Low Level
Time, t
75