6.3 Parameters Configuration

6.3.1 Global parameters Settings

Global parameters do not depend on selected profile; they are common for all profiles. To
configure these parameters choose the TAB named "Global Parameters" and make all necessary
changes (Figure 21)
Table 8 Global parameters description
Parameter Name
Profile change on
event
Record Settings
Accelerometer
settings
Figure 21 FM6320 Global parameters
Allows selecting profile switching method. When 'Profile change on
event' is disabled – FM6320 switches profiles depending on GSM
operator code method. Otherwise it switches profiles depending on I/O
events (see details in chapter 7.2).
Are used to switch between two data sending modes: starting from
newest records or starting from oldest record. Active data link timeout
defines how many seconds should FM6320 keep connection to the
server before disconnecting after successful data transfer. Note that
even if it disconnects from server, it always keep active GPRS session.
Defines accelerometer how many seconds should movement be
detected by accelerometer in order to set movement for FM6320
application and how many seconds after movement is not detected by
accelerometer FM6320 application should treat like movement is still
there.