6.3.3.3.3 Trip

Trip window offers user to configure Trip feature. If Trip is enabled configuration of
parameters is available:
 Start Speed – speed, which is detected as minimum speed to indicate Trip start.
 Ignition Off Timeout – timeout to wait if ignition was off, to detect Trip stop.
 Continuous distance counting – Not or Continuous can be chosen in Global
parameters (see paragraph"Global parameters Settings"). For this feature I/O
Odometer must be enabled.
If I/O Odometer is enabled and Continuous distance counting variable is set to Continuous,
Trip distance is going to be counted continuously (from Trip start to Trip stop). This value is
written to I/O Odometer value field. When Trip is over and next Trip begins, Odometer value is
not reset to zero, it is counted continuously again.
If I/O Odometer is enabled and Continuous Distance Counting variable is set to "Not", then
distance is going to be counted only between every record made. This value is written to I/O
Odometer value field and reset to zero every new record until Trip stops. If later all Odometer
values are summed up manually user gets distance driven over the whole Trip period.
Figure 30 FM6320 Operator List Configuration
Figure 31 FM6320 Features->Trip Configuration