(are always sent (with every record) to server if enabled)
Nr.
Property Name
16
External Voltage
17
GNSS status
18
Movement sensor
19
Odometer value
20
GSM Operator
21
Speed
22
iButton ID
23
GSM signal level
24
Deep Sleep
25
PCB Temperature
26
Dallas ID 1
27
Dallas Temperature 1
28
Dallas ID 2
29
Dallas Temperature 2
30
Dallas ID 3
31
Dallas Temperature 3
32
Dallas ID 3
33
Dallas Temperature 4
34
Fuel Counter
35
Ignition
36
RFID
37
LLS #1Fuel
38
LLS #1 temperature
39
LLS #2 Fuel
40
LLS #2 temperature
41
LLS #3 Fuel
42
LLS #3 temperature
43
LLS #4 Fuel
44
LLS #4 temperature
45
LLS #5 Fuel
46
LLS #5 temperature
Permanent I/O elements
Bytes
2
Voltage: mV, 0 – 30 V
0-off/ 1-no antenna / 2- no fix/ 3-got fix/ 4-sleep/ 5-
2
over current
1
0 – not moving, 1 – moving.
4
Distance between two records: m
4
Currently used GSM Operator code
2
Value in km/h, 0 – xxx km/h
8
iButton ID number
2
Value in scale 1 – 5
1
0 – not deep sleep mode, 1 – deep sleep mode
2
10 * Degrees ( °C )
9
Shows ID of first Dallas sensor
8
10 * Degrees ( °C ), -55 - +115, if 3000 – Dallas error
9
Shows ID of second Dallas sensor
8
10 * Degrees ( °C ), -55 - +115, if 3000 – Dallas error
9
Shows ID of third Dallas sensor
8
10 * Degrees ( °C ), -55 - +115, if 3000 – Dallas error
9
Shows ID of fourth Dallas sensor
8
10 * Degrees ( °C ), -55 - +115, if 3000 – Dallas error
4
Difference of generated impulses on two signal lines
1
0 – ignition is off, 1 – ignition is on
9
Displays activated RFID card ID
Fuel level, measured by LLS sensor on COM2, in kvants
3
or liters.
Fuel temperature, measured by LLS sensor on COM2, in
2
degrees Celsius.
Fuel level, measured by LLS sensor on COM2, in kvants
3
or liters.
Fuel temperature, measured by LLS sensor on COM2, in
2
degrees Celsius.
Fuel level, measured by LLS sensor on COM2, in kvants
3
or liters.
Fuel temperature, measured by LLS sensor on COM2, in
2
degrees Celsius.
Fuel level, measured by LLS sensor on COM2, in kvants
3
or liters.
Fuel temperature, measured by LLS sensor on COM2, in
2
degrees Celsius.
Fuel level, measured by LLS sensor on COM2, in kvants
3
or liters.
Fuel temperature, measured by LLS sensor on COM2, in
2
degrees Celsius.
Description