CAN#0 I/O LowLevel
Parameter defines low value of triggered I/O property. This parameter is used to set
thresholds for CAN I/O properties to generate events.
Table 16 CAN#0 I/O LowLevel
Minimum
Maximum
value
value
0
9999999
CAN#0 I/O Logic Operand
Parameter defines when event is sent: 0 is event on exit, 1 – on entrance, 2 – on both, 3 –
monitoring, 4 – hysteresis, 5 – on change.
Table 17 CAN#0 I/O Logic Operand
Minimum
Maximum
value
value
0
5
CAN#0 I/O Averaging Constant
Parameter defines I/O property sample length to average. If no averaging needed default
value is 1.
Table 18 CAN#0 I/O Averaging Constant
Minimum
Maximum
value
value
1
99999999
CAN#0 I/O CAN Type ID
Parameter defines CAN element ID length. CAN element ID could be 11 or 29 bits length.
For 11 bits ID parameter value is 0, for 29 bits ID – 1.
Recommended
Goes with (depends on)
value
CAN#0 I/O Logic Operand
0
CAN#0 I/O Averaging Constant
CAN#0 I/O CAN Type ID
CAN#0 I/O OutputDataMask
Recommended
Goes with (depends on)
value
0
CAN#0 I/O Averaging Constant
CAN#0 I/O CAN Type ID
CAN#0 I/O OutputDataMask
Recommended
Goes with (depends on)
value
1
CAN#0 I/O Logic Operand
CAN#0 I/O CAN Type ID
CAN#0 I/O OutputDataMask
parameters
CAN#0 I/O Priority
CAN#0 I/O HighLevel
CAN#0 I/O CAN ID
parameters
CAN#0 I/O Priority
CAN#0 I/O HighLevel
CAN#0 I/O LowLevel
CAN#0 I/O CAN ID
parameters
CAN#0 I/O Priority
CAN#0 I/O HighLevel
CAN#0 I/O LowLevel
CAN#0 I/O CAN ID
Value type
S32
Value type
U8
Value type
S32