POINT
POINT
POINT
Precautions for device registration
(1) Data type
Device monitor screens display the data type as shown below.
• DW: 32-bit (two-word) module
• Nothing displayed : 16-bit (one-word) module
(2) CPU No. specification
Changing the CPU No. after registering devices cancels the registration for all the devices.
Check the CPU No. before registering the devices.
(3) Station No. specification
Changing the station No. after registering devices cancels the registration for all the devices.
Check the station No. before registering the devices.
(4) N/W (Network) No. specification
Changing the N/W No. after registering devices cancels the registration for all the devices.
Check the N/W No. before registering the devices.
(5) Holding registered devices
The registration for the devices is not canceled after exiting the device monitor.
Restarting the GOT cancels the registration for all the devices.
(6) The number of registered devices
The number of registered devices must be within the maximum number of devices that can
be displayed on the GOT.
For registering an additional device, the registration for the device in the top line is canceled
and the additional device is displayed in the bottom.
16.1 Device Monitor Function
16
16 - 9