Operator configuration of PFC is used only when the port is configured in a
manual role. When interoperating with other equipment in a manual role,
the peer equipment must be configured with identical PFC priorities and
VLAN assignments. Interfaces not enabled for PFC ignore received PFC
frames. Ports configured in auto-upstream or auto-downstream roles receive
their PFC configuration from the configuration source and ignore any
manually configured information.
When using links in a port channel, PFC must be configured on all of the
individual links in the port channel, as it operates on a link-local basis.
NOTE:
This feature is configurable on physical full duplex interfaces only. To
enable PFC on a LAG interface, the member interfaces must have the same
configuration.
When PFC is disabled, the interface defaults to the IEEE 802.3 Annex 31B
flow control setting for the interface. PFC is disabled by default.
If you enable priority-based flow control for a particular priority value on an
interface, ensure that VLAN tagging is enabled on the interface so that the
802.1p priority values are carried through the network (see "VLAN Tagging"
on page 565). Additionally, make sure that 802.1p priority values are mapped
to CoS values (see "Configuring Class-of-Service" on page 1153). If DCBX is
enabled, the manually configured PFC parameters (no-drop priorities) must
match the peers PFC parameters. If they do not match, PFC will not be
operationally enabled and the port will continue to operate in the configured
legacy flow control mode (IEEE 802.3 Annex 31B mode or none).
PFC can be configured using the web interface and the command line
interface.

Configuring PFC Using the Web Interface

This section provides information about the OpenManage Switch
Administrator pages to use to view and configure PFC on PowerConnect
M6220/M6348/M8024/M8024-k switch. For details about the fields on a page,
click
at the top of the page.
NOTE:
FIP snooping can be enabled, configured, and monitored only by using
the CLI.
840
Configuring Data Center Bridging Features