Stack member number— The unit number within the stack. The range is
1–12. The default unit number for a switch that has not been in a stack is
1. To view the member number assigned to each switch in a stack, use the
show switch command. For non-stacking switches (PCM8024), the unit
number is always 1.
Module (slot) number—The expansion module slot. Integrated internal
and external ports have a slot number of 0. For switches that provide one
or two expansion slots, the slot number is 1 or 2.
Port number—The number assigned to the port.
For example, to enter Interface Configuration mode for Gigabit Ethernet
port 10 on a switch that is not part of a stack, use the following command:
console(config)#interface gigabitEthernet 1/0/10
NOTE:
When you enter Interface Configuration mode, the command prompt
changes and identifies the interface. In the previous example, the command
prompt becomes console(config-if-Gi1/0/10)#
To enter Interface Configuration mode for 10-Gigabit Ethernet port 6 on
stack member 3, use the following command:
console(config)#interface tengigabitEthernet 3/0/6
To enter Interface Configuration mode for port 1 on a 10-Gigabit Ethernet
module in slot 1, use the following command:
console(config)#interface tengigabitEthernet 1/1/1
For many features, you can configure a range of interfaces. When you enter
Interface Configuration mode for multiple interfaces, the commands you
execute apply to all interfaces specified in the range.
To enter Interface Configuration mode for a range of interfaces, include the
keyword range and specify the interfaces to configure. For example, to apply
the same configuration to ports 1-10 on a standalone switch, use the
following command:
console(config)#interface range gigabitEthernet
1/0/1-10
To enter Interface Configuration mode for ports 3, 4, 5, 12, and 14 on a
standalone switch, use the following command:
console(config)#interface range gigabitEthernet
1/0/3-5,1/0/12,1/0/14