5.9.4 Installing IP Phones at a Remote Site with a Built-in Media Relay Gateway
Application
RTP (UDP)
FTP
*1
The port number ranges must be within the range of RTP/RTCP for NAT traversal (16000–18047).
Up to 4 IP addresses can be assigned to the KX-NS1000's optional DSP cards. The following example shows the port number ranges
set for each IP address:
[Example]
Port forward destination
DSP#1–1
DSP#1–2
DSP#2–1
DSP#2–2
For the IP-CS (KX-NS0154 only):
Application
PTAP
MGCP
RTP (UDP)
298
Installation Manual
LAN Side Port Number
Start/End RTP (UDP) Port No.
(Use port numbers that are in the
range of the RTP ports that the
KX-NS1000 uses.)
*1
Make sure the RTP Start Port (UDP) and the RTP End Port (UDP) specified
for the router are in the range of the RTP ports that the KX-NS1000 uses.
For the range of RTP port numbers that the KX-NS1000 uses, refer to "Port
Numbers for Optional DSP Cards" in "8.5 Port Security".
The port number used for the FTP
protocol. This is used for software
updates.
LAN Side Port Number
Signalling (PTAP) UDP Port No.
(Server)
(refer to PC Programming Manual
"9.18 PBX Configuration—[1-1]
Configuration—Slot—V-IPCS4
—Card Property")
Signalling (MGCP) UDP Port No.
(Server)
(refer to PC Programming Manual
"9.18 PBX Configuration—[1-1]
Configuration—Slot—V-IPCS4
—Card Property")
Start/End RTP (UDP) Port No.
(Use port numbers that are in the
range of the RTP ports that the
KX-NS1000 uses.)
*1
Make sure the RTP Start Port (UDP) and the RTP End Port (UDP) specified
for the router are in the range of the RTP ports that the KX-NS1000 uses.
For the range of RTP port numbers that the KX-NS1000 uses, refer to "Port
Numbers for Optional DSP Cards" in "8.5 Port Security".
WAN Side Port Number
Start/End RTP (UDP) Port No.
(Use port numbers that are in the
range of the RTP ports that the
KX-NS1000 uses.)
NAT - FTP Server Port No.
(Use the same value as in step 5 of
"Programming the KX-NS1000 with
Built-in Media Relay Gateway".)
Port number range
16000–16511
16512–17023
17024–17535
17536–18047
WAN Side Port Number
Signalling (PTAP) UDP Port No.
(Server)
(refer to PC Programming Manual
"9.18 PBX Configuration—[1-1]
Configuration—Slot—V-IPCS4
—Card Property")
NAT - MGCP Server Port No. for
IP-CS
(Use the same value as in step 5 of
"Programming the KX-NS1000 with
Built-in Media Relay Gateway".)
Start/End RTP (UDP) Port No.
(Use port numbers that are in the
range of the RTP ports that the
KX-NS1000 uses.)
*1
*1
*1
*1