5.3 Starting Web Maintenance Console
[Exchanging cards]
•
During system data conversion, if the number of optional physical service cards exceeds the maximum
number of allowed by the selected system components type, information for the cards exceeding the
limit (including extension numbers and trunk numbers) is discarded.
At this time, any data related to the discarded card is processed in the same way as when an optional
card is deleted using the normal procedure (e.g., if the extension number is registered as a member
of an incoming call group, the extension number will not be deleted from the group).
•
Converting virtual card information from data (Type 1) to Type 2 or 3 is processed according to the
following order of priority:
–
V-IPEXT32 ® V-SIPEXT32 ® V-UTEXT32
•
You can decide whether to replace a discarded extension card with an alternate extension card during
the conversion. If you use an alternate extension card, you can also specify the card type.
•
The alternate extension card can inherit the information of each extension registered to the discarded
card. However, data specific to the discarded card's type (e.g., port settings for the discarded card)
cannot be inherited.
[Data related to Tenant Numbers]
•
During system data conversion from system component type 3 to system component type 1 or 2,
information for the following data is deleted, due to a decrease in the number of tenants.
•
Time Service Mode
•
Music On Hold
•
Operator (Extension Number)
•
ARS Mode
•
Authorisation Code for Tenant
*1
Refer to "14.6 PBX Configuration—[6-6] Feature—Tenant" in the PC Programming Manual.
*2
Refer to "16.5 PBX Configuration—[8-5] ARS—Carrier—Authorisation Code for Tenant" in the PC Programming Manual.
[Conversion of System Speed Dialling]
•
During system data conversion from system component type 1 or 2 to system component type 3, the
number of tenants increases, but some system data is deleted.
Therefore, data conversion proceeds as follows:
1.
Basic Memory for systems is inherited regardless of the change to the system component type.
2.
System data for each tenant is converted according to the following table.
System Component Type 1/ System
Tenant 1–32:
System speed dial entries 1–300
Tenant 1–32:
System speed dial entries 301–600
Tenant 1–32:
System speed dial entries 601–900
Tenant 1–32:
System speed dial entries 901–1000
None
212
Installation Manual
*1
*1
*1
*1
*2
Component Type 2
System Component Type 3
Tenant 1–32:
System speed dial entries 1–300
None
None
None
Tenant 33–128:
System speed dial entries 1–300