5.3 Starting Web Maintenance Console
KX-TDA100D PBX can be added to the base KX-NS1000 system data, and then converted for use in a Slave
unit. The conversion results are used as the system data of a KX-NS1000 (Master unit) that controls one or
more Slave units.
1.
Connect a PC to a KX-TDE series, KX-NCP series or KX-TDA100D PBX and then start the Unified
Maintenance Console. For details about connecting a PC to a PBX or for details about the Unified
Maintenance Console, refer to the appropriate documentation.
2.
In the Unified Maintenance Console, save the PBX's system data file (DxSYS
For details about saving the system data file to the PC, refer to the appropriate documentation.
3.
Start Web Maintenance Console for the KX-NS1000 in Off-line mode.
4.
In the Programme Launcher, click Database Converter.
5.
In Select Converter Type, click Slave data converter.
6.
In TDE/NCP/TDA100D System Data, select the appropriate option according to whether a legacy gateway
is connected.
7.
In Select Original File Name, select the system file (DxSYS) you saved in step 2 as the file to convert.
8.
In NS1000 System Data to Add Site, select the system file (DCSYS) for the Master unit as the file to
convert.
9.
In Convert Site List, the site ID and the site information is displayed.
10.
Click Next. In Convert Image, an image of converting the file to the KX-NS1000 is displayed on the screen.
11.
Click Next. In Convert Option, you can select whether each item displayed on screen will be converted.
12.
Specify the following Slave unit parameters as necessary:
CO & Incoming Settings
Numbering Plan–Main–Other PBX Extension
Maintenance–SNMP–System Setting–MIB–SysName
13.
Click Next. In Setup Slave Unit, specify the necessary information for the Slave units. Operation and
programming items are same as the Add Site Wizard. For more information, refer to "5.5 Programming a
One-look Network".
14.
Click Next. If you are converting a shelf of a KX-TDE600 for two sites, after you finish configuring the first
site, return to step 13 and configure the second site.
After you have finished, continue to the next step. For all other PBXs, continue to the next step.
15.
After conversion is complete, you can click Save on the Result of Converting screen and save the results
file (ConvertReport.txt) to your PC.
16.
On the Save Converted File of System Data screen, save the created DCSYS file.
17.
To add an additional Slave unit with another DxSYS file, click Continue and return to step 7. If you have
finished adding Slave units, click Finish and continue to the next step.
18.
In Select Next Step, select the next step and then click OK. Conversion is complete.
19.
Start Web Maintenance Console, and click Open -Offline Mode in the Programme Launcher.
20.
Select the created DCSYS file, and configure any additional required parameters.
For details about the parameters, refer to the PC Programming Manual.
21.
Start the KX-NS1000, and then transfer the system data file (DCSYS) to the PBX.
For details about transferring the file, refer to "1.2.2 PC Programming Using Off-line Mode—Uploading
Programmed Settings to the PBX" in the PC Programming Manual.
*1
"DxSYS" refers to the following:
KX-NCP500/KX-NCP1000: DBSYS
KX-TDE100/KX-TDE200: DMSYS
KX-TDA100D: DDSYS
KX-TDE600: DGSYS
The software version for KX-TDE series, KX-NCP series or KX-TDA100D PBXs must meet the latest version requirements shown
*2
in the Data Converter tool. If the requirements are not met, you must use the Unified Maintenance Console to upgrade the version
to the one shown in the table below, and then save the DxSYS file.