SRC 1 I2 Mag................................................Metered negative-sequence current magnitude for source 1
SRC 2................................................................The analog parameters shown above are available for sources
Power metering analog operands
SRC 1 P............................................................Metered three-phase real power for source 1
SRC 1 Pa.........................................................Metered phase A real power for source 1
SRC 1 Pb.........................................................Metered phase B real power for source 1
SRC 1 Pc .........................................................Metered phase C real power for source 1
SRC 1 Q...........................................................Metered three-phase reactive power for source 1
SRC 1 Qa ........................................................Metered phase A reactive power for source 1
SRC 1 Qb ........................................................Metered phase B reactive power for source 1
SRC 1 Qc.........................................................Metered phase C reactive power for source 1
SRC 1 S............................................................Metered three-phase apparent power for source 1
SRC 1 Sa.........................................................Metered phase A apparent power for source 1
SRC 1 Sb.........................................................Metered phase B apparent power for source 1
SRC 1 Sc .........................................................Metered phase C apparent power for source 1
SRC 1 PF .........................................................Metered three-phase power factor for source 1
SRC 1 PF A .....................................................Metered phase A power factor for source 1
SRC 1 PF B .....................................................Metered phase B power factor for source 1
SRC 1 PF C .....................................................Metered phase C power factor for source 1
SRC 2................................................................The analog parameters shown above are available for sources
Energy metering analog operands
SRC 1 Pos Watth.........................................Metered three-phase real power for source 1
SRC 1 Neg Watth .......................................Metered phase A real power for source 1
SRC 1 Pos Varh............................................Metered phase B real power for source 1
SRC 1 Neg Varh...........................................Metered phase C real power for source 1
SRC 2................................................................The analog parameters shown above are available for sources
Voltage metering analog operands
SRC 1 Vag RMS............................................Metered RMS phase A to ground voltage for source 1
SRC 1 Vbg RMS............................................Metered RMS phase B to ground voltage for source 1
SRC 1 Vcg RMS............................................Metered RMS phase C to ground voltage for source 1
SRC 1 Vag Angle.........................................Metered phase A to ground voltage angle for source 1
SRC 1 Vag Mag............................................Metered phase A to ground voltage magnitude for source 1
SRC 1 Vbg Angle.........................................Metered phase B to ground voltage angle for source 1
SRC 1 Vbg Mag............................................Metered phase B to ground voltage magnitude for source 1
SRC 1 Vcg Angle .........................................Metered phase C to ground voltage angle for source 1
SRC 1 Vcg Mag............................................Metered phase C to ground voltage magnitude for source 1
SRC 1 Vab RMS............................................Metered RMS phase A to B voltage for source 1
SRC 1 Vbc RMS............................................Metered RMS phase B to C voltage for source 1
SRC 1 Vca RMS............................................Metered RMS phase C to A voltage for source 1
SRC 1 Vab Angle.........................................Metered phase A to B voltage angle for source 1
SRC 1 Vab Mag............................................Metered phase A to B voltage magnitude for source 1
SRC 1 Vbc Angle .........................................Metered phase B to C voltage angle for source 1
SRC 1 Vbc Mag............................................Metered phase B to C voltage magnitude for source 1
SRC 1 Vca Angle .........................................Metered phase C to A voltage angle for source 1