CHAPTER 11: METERING

Metering FlexAnalog parameters

PLUS
D90
LINE DISTANCE PROTECTION SYSTEM – INSTRUCTION MANUAL
PMU 1 POWER TRIGGER..........................Asserted when the overpower trigger of Phasor Measurement
PMU 1 ROCOF TRIGGER...........................Asserted when the rate of change of frequency trigger of
PMU 1 TRIGGERED.....................................Asserted when the Phasor Measurement Unit 1 triggers. No
PMU 1 VOLT TRIGGER ...............................Asserted when the abnormal voltage trigger of Phasor
Phasor Measurement Unit one-shot operands
PMU ONE-SHOT EXPIRED .......................Asserted after the one-shot operation executes.
PMU ONE-SHOT OP...................................Asserted upon one-shot operation.
PMU ONE-SHOT PENDING......................Asserted while the one-shot operation is pending. That is, while
The following metering FlexAnalog parameters (analog operands) are available for the
Plus
D90
. They are listed alphabetically by operand syntax.
Phasor Measurement Unit analog operands
PMU 1 Conf Ch ............................................Metered configuration change counter value for Phasor
PMU 1 df dt ...................................................Metered frequency rate of change value for Phasor
PMU 1 Freq....................................................Metered frequency value for Phasor Measurement Unit 1
PMU 1 Num Triggers ................................Metered number of triggers for Phasor Measurement Unit 1
PMU 1 Ia Mag...............................................Metered phase A current magnitude for Phasor Measurement
PMU 1 Ia Ang................................................Metered phase A current angle for Phasor Measurement Unit 1
PMU 1 Ib Mag...............................................Metered phase B current magnitude for Phasor Measurement
PMU 1 Ib Ang................................................Metered phase B current angle for Phasor Measurement Unit 1
PMU 1 Ic Mag...............................................Metered phase C current magnitude for Phasor Measurement
PMU 1 Ic Ang................................................Metered phase C current angle for Phasor Measurement Unit 1
PMU 1 Ig Mag...............................................Metered ground current magnitude for Phasor Measurement
PMU 1 Ig Ang................................................Metered ground current angle for Phasor Measurement Unit 1
PMU 1 I0 Mag...............................................Metered zero-sequence current magnitude for Phasor
PMU 1 I0 Ang................................................Metered zero-sequence current angle for Phasor Measurement
PMU 1 I1 Mag...............................................Metered positive-sequence current magnitude for Phasor
PMU 1 I1 Ang................................................Metered positive-sequence current angle for Phasor
PMU 1 I2 Mag...............................................Metered negative-sequence current magnitude for Phasor
PMU 1 I2 Ang................................................Metered negative-sequence current angle for Phasor
Unit 1 operates.
Phasor Measurement Unit 1 operates.
events or targets are generated by this operand.
Measurement Unit 1 operates.
the present time is before the scheduled one-shot time.
Measurement Unit 1
Measurement Unit 1
Unit 1
Unit 1
Unit 1
Unit 1
Measurement Unit 1
Unit 1
Measurement Unit 1
Measurement Unit 1
Measurement Unit 1
Measurement Unit 1
METERING FLEXANALOG PARAMETERS