COMMUNICATION LOGIC OPERANDS

Communication logic operands

Customize the operands

168
The following communication logic operands are available for the D90
alphabetically by operand syntax. If required, these operands can be assigned user-
defined names through the Settings > Configure FlexOperands menu.
Direct device operands
CH 1 DIR DEV 1 OFF..................................Asserted when direct device 1 on channel 1 is off.
CH 1 DIR DEV 1 ON....................................Asserted when direct device 1 on channel 1 is on.
CH 2 DIR DEV 1 OFF..................................Asserted when direct device 1 on channel 2 is off.
CH 2 DIR DEV 1 ON....................................Asserted when direct device 1 on channel 2 is on.
CH 1 DIR DEV 2... ........................................The operands listed above are available for direct devices 2
CH 2 DIR DEV 2... ........................................The operands listed above are available for direct devices 2
Direct input and output operands
DIRECT INPUT 1 ON...................................Asserted when direct input 1 is on.
DIRECT INPUT 2...........................................The operands listed above are available for direct inputs 2
Remote double-point status input operands
RemDPS Ip 1 BAD ......................................Asserted when remote double-point status input 1 is in the bad
RemDPS Ip 1 INTERM ...............................Asserted when remote double-point status input 1 is in the
RemDPS Ip 1 OFF.......................................Asserted when remote double-point status input 1 is in the off
RemDPS Ip 1 ON.........................................Asserted when remote double-point status input 1 is in the on
RemDPS Ip 2.................................................The operands listed above are also available for remote
Teleprotection input and output operands
TELEPRO CH1 CRC FAIL...........................Asserted when the CRC detects packet corruption on
TELEPRO CH1 FAIL.....................................Asserted when teleprotection inputs are not received for more
TELEPRO CH1 FAIL OFF ...........................Asserted when teleprotection has failed for channel 1.
TELEPRO CH1 PKT LOST..........................Asserted when the CRC detects a lost packet on teleprotection
TELEPRO CH2 CRC FAIL...........................Asserted when the CRC detects packet corruption on
TELEPRO CH2 FAIL.....................................Asserted when teleprotection inputs are not received for more
TELEPRO CH2 FAIL OFF ...........................Asserted when teleprotection has failed for channel 2.
TELEPRO CH2 PKT LOST..........................Asserted when the CRC detects a lost packet on teleprotection
Select the Settings > Configure FlexOperands menu to open the user-configurable
operands window.
through 16 on channel 1.
through 16 on channel 2.
through 96.
state.
intermediate state.
(open) state.
(closed) state.
double-point status inputs 2 through 16.
teleprotection channel 1.
than four cycles on channel 1.
channel 1.
teleprotection channel 2.
than four cycles on channel 2.
channel 2.
PLUS
D90
LINE DISTANCE PROTECTION SYSTEM – INSTRUCTION MANUAL
CHAPTER 6: COMMUNICATIONS