Unlock (Command: 1630) - Mitsubishi Electric MELSEC IQ-R series Reference Manual

Programmable controller
Hide thumbs Also See for MELSEC IQ-R series:
Table of Contents

Advertisement

Unlock (command: 1630)

Specify the remote password to unlock the module. (The module can communicate.)
If the incorrect password is entered several times, the password is locked out and cannot be cleared for a
while.
When the command is sent to the unlocked module, the unlock status is not changed. (The password
verification is not performed.)
Message format
The following shows the message format of the request data and response data of the command.
■Request data
Command
Subcommand
■Response data
There is no response data for this command.
Data specified by request data
■Command
ASCII code
1
6
3
0
31
36
33
30
H
H
H
H
■Subcommand
ASCII code
0
0
0
0
30
30
30
30
H
H
H
H
■Remote password length
Specify the number of characters of remote password. (Page 170 Remote password length)
■Remote password
Specify the set remote password. (Page 170 Remote password)
Remote password
Remote password
length
Binary code
30
16
H
H
Binary code
00
00
H
H
11 CONTROL MODULE OPERATION
11.3 Remote Password
11
181

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsecq seriesMelsec l series

Table of Contents