Mitsubishi Electric MELSEC IQ-R series Reference Manual page 279

Programmable controller
Hide thumbs Also See for MELSEC IQ-R series:
Table of Contents

Advertisement

■Data communication in ASCII code
(Request data)
Subcommand
0
6
3
0
0
0
0
30
36
33
30
30
30
30
H
H
H
H
H
H
H
Word device registration (first point)
Monitoring start device
D
*
0
0
0
44
2A
30
30
30
H
H
H
H
H
Word device registration (second point)
Monitoring start device
W
*
0
0
0
57
2A
30
30
30
H
H
H
H
H
W100 to D107
Bit device registration (first point)
Monitoring start device
M
*
0
0
0
4D
2A
30
30
30
H
H
H
H
H
CPU error monitoring registration (Fixed value)
0
1
0
0
0
30
31
30
30
30
H
H
H
H
H
(Response data)
When the condition (D0 = 99) of word device registration (first point) is established
Number
Programmable
of registered
Fixed value
controller CPU
word blocks
monitoring function
2
1
0
2
0
2
0
31
30
32
30
32
30
31
32
H
H
H
H
H
H
H
When the condition (M0 ≠ OFF) of bit device registration (first point) is established
Number
Programmable
of registered
Fixed value
controller CPU
monitoring function
word blocks
2
1
0
2
0
2
0
32
31
30
32
30
32
30
30
H
H
H
H
H
H
H
When the condition of CPU error monitoring is established(Module warning being generated)
Number
Programmable
of registered
Fixed value
controller CPU
word blocks
monitoring function
1
0
2
0
2
0
2
32
31
30
32
30
32
30
30
H
H
H
H
H
H
H
In the figure (1) and (2), set the value of "ASCII Code" in the table of "Device data" of each response data.
The order of device data differ depending on the setting of "Word/byte units designation" in Engineering tool.
Programmable
Cycle
controller CPU
Cycle time
time unit
monitoring function
0
0
1
0
0
1
E
0
30
30
31
30
30
31
45
30
H
H
H
H
H
H
H
Number of
registered points
0
0
0
0
0
0
4
0
30
30
30
30
30
30
34
30
H
H
H
H
H
H
H
D0 to D3
Number of
registered points
1
0
0
0
0
0
8
0
31
30
30
30
30
30
38
30
H
H
H
H
H
H
H
Number of
registered points
0
0
0
0
0
0
2
0
30
30
30
30
30
30
32
30
H
H
H
H
H
H
H
M0 to M31
0
0
0
0
0
0
1
30
30
30
30
30
30
31
30
H
H
H
H
H
H
H
Number
CPU error
of registered
Monitoring start device
monitoring
bit blocks
1
0
0
0
0
D
*
0
30
30
30
30
44
2A
30
H
H
H
H
H
H
H
H
Number
CPU error
of registered
Monitoring start device
monitoring
bit blocks
0
0
1
0
M
*
0
30
31
30
30
4D
2A
30
H
H
H
H
H
H
H
H
Number
CPU error
of registered
monitoring
bit blocks
0
0
0
0
1
0
1
0
30
30
30
31
30
31
30
H
H
H
H
H
H
H
H
13 SERIAL COMMUNICATION MODULE DEDICATED COMMANDS
Number
Number
Transmission
of registered
of registered
method
word blocks
bit blocks
2
0
0
0
2
0
1
32
30
30
30
32
30
31
H
H
H
H
H
H
H
H
Monitoring
Monitoring
condition value
condition
0
0
1
0
0
6
3
30
30
31
30
30
36
33
H
H
H
H
H
H
H
H
D0=99
Monitoring
Monitoring
condition
condition value
0
0
2
0
0
0
0
30
30
32
30
30
30
30
H
H
H
H
H
H
H
H
W100≠0
Monitoring
Monitoring
condition
condition value
0
0
2
0
0
0
0
30
30
32
30
30
30
30
H
H
H
H
H
H
H
H
M0≠OFF
0
0
0
5
0
0
0
1
30
30
35
30
30
30
31
H
H
H
H
H
H
H
H
Number of
registered points
0
0
0
0
0
0
0
0
30
30
30
30
30
30
30
30
H
H
H
H
H
H
H
Word device information
Number of
registered points
0
0
0
0
0
0
0
0
30
30
30
30
30
30
30
30
H
H
H
H
H
H
H
Bit device information
Fixed value
0
0
0
0
0
0
0
0
30
30
30
30
30
30
30
30
H
H
H
H
H
H
H
CPU status information
13.5 Programmable controller CPU monitoring function
CPU error
monitoring
0
1
30
31
H
H
Device data
4
(1)
34
H
H
Device data
2
(2)
32
H
H
Device data
1
0
0
0
1
32
30
30
30
32
H
H
H
H
H
H
13
277