■Password
Specify the password of the access target file. (Page 195 Password)
■Drive No.
Specify the access target drive. (Page 198 Drive No.)
Program memory (drive No.0) of RCPU cannot be specified.
■Number of file name characters, file name
Specify the file name to be copied. (Page 202 File name specification)
Communication example (files for MELSEC-Q series)
Copy the file under the following conditions:
• Copy source/destination password: 1234
• Drive No. of copy source, drive No. of copy destination: 0
• Copy source file name: ABC.QPG
• Copy source file name: CBA.QPG
■Data communication in ASCII code
(Request data)
Subcommand
1
8
2
4
0
0
0
0
31
38
32
34
30
30
30
30
H
H
H
H
H
H
H
H
Password
Drive No.
1
2
3
4
0
0
31
32
33
34
30
30
H
H
H
H
H
H
■Data communication in binary code
(Request data)
Subcommand
Fixed values (8 bytes)
24
18
00
00
00
00
00
H
H
H
H
H
H
H
Number of file name characters
Password
Drive No.
1
2
3
4
31
32
33
34
00
00
H
H
H
H
H
Fixed values (16 characters)
Password
0
0
0
0
1
2
3
30
30
...
30
30
31
32
33
H
H
H
H
H
H
H
Number of file name characters
0
0
0
0
0
7
A
B
30
30
30
30
30
37
41
42
H
H
H
H
H
H
H
H
Copy source
Password
1
2
00
00
00
00
00
31
32
H
H
H
H
H
H
H
File name
A
B
C
.
Q
07
00
41
42
43
2E
51
H
H
H
H
H
H
H
Copy source
Drive No.
Number of file name characters
4
0
0
0
0
0
0
0
34
30
30
30
30
30
30
30
H
H
H
H
H
H
H
H
Copy destination
File name
C
.
Q
P
G
43
2E
51
50
47
H
H
H
H
H
Number of file name characters
Drive No.
3
4
C
33
34
00
00
07
00
43
H
H
H
H
H
H
H
Copy destination
P
G
50
47
H
H
H
File name
7
C
B
A
.
Q
P
G
37
43
42
41
2E
51
50
47
H
H
H
H
H
H
H
H
File name
B
A
.
Q
P
G
42
41
2E
51
50
47
H
H
H
H
H
H
12 FILE CONTROL
12.5 File Creation and Deletion