Communication example
Read the extended file registers directly in the CPU module with E71 mounted under the following conditions.
• Block number: No.0
• Device number: R70
• Number of device points: 4 points
■Data communication in ASCII code
(Request data)
Block No.
0
0
0
2
5
2
2
30
30
30
32
35
32
32
H
H
H
H
H
H
H
(Response data)
Data for the number of specified device points
1
2
3
4
8
7
6
31
32
33
34
38
37
36
H
H
H
H
H
H
H
(R70 in No.0)
(R71 in No.0)
■Data communication in binary code
(Request data)
Device number
Number of device points
46
00
00
00
20
52
04
H
H
H
H
H
H
H
(Response data)
Data for the number of specified device points
34
12
65
87
3F
01
20
H
H
H
H
H
H
(R70 in No.0)
(R72 in No.0)
(R71 in No.0)
(R73 in No.0)
Device number
0
0
0
0
0
0
0
30
30
30
30
30
30
30
H
H
H
H
H
H
H
5
0
1
3
F
0
0
35
30
31
33
46
30
30
H
H
H
H
H
H
H
(R72 in No.0)
(R73 in No.0)
00
H
00
H
H
Number of device points
4
6
0
4
0
0
34
36
30
34
30
30
H
H
H
H
H
H
2
0
32
30
H
H
18 COMMUNICATING USING 1E FRAMES