Data to be specified in command

Device number
■ACPU common command
Specify the block number and device number with 7 digits.
• When the block number is less than 2 digits
'Block number (2 digits)' + 'R' + 'Device number (4 digits)'
• When the block number is 3 digits
'Block number (3 digits)' + 'Device number (4 digits)'
Specification
When the block No. is less than 2 digits
example
0 5 R 8 1 9 0
■AnA/AnUCPU common command
Specify the address from device number 0 of block number 1 in 7 digits.
Page 373 Device number (address) specification using AnA/AnUCPU common commands
Specification
Specifying R10 of block number 1
example 1
Specification
Specifying R8 of block number 2
example 2
(2-1) × 8192+8
Block No.
17 COMMUNICATING USING 1C FRAMES
374
17.5 Read and Write Extended File Register
When the block No. is 3 digits
1 0 2 8 1 9 0
Device No.
Block No.
"0" in the first digits (for example, the
leading three digits indicated in
0008200) can be specified by
spaces (20H).
Block points
Device No.
Block No.