Accessible modules
The following modules in the accessible range can be accessed
However, the commands that can be used have some restrictions. (Page 471 Accessible Modules for Each Command)
For the access to A series and QnA series modules, refer to the following sections.
• For QnA series: Page 286 MELSEC-QnA SERIES SUPPORTED SPECIFICATIONS
• For A series: Page 342 MELSEC-A SERIES SUPPORTED SPECIFICATIONS
For the restrictions for model name and version of the supported module, refer to the manual of each module.
■Connectable modules
The following modules can be connected from an external device with the serial communication.
• Serial communication module
• CPU modules that have serial communication function
For the serial communication functions, refer to the user's manual of the CPU module used.
 MELSEC-L CPU Module User's Manual (Function Explanation, Program Fundamentals)
 QnUCPU User's Manual (Function Explanation, Program Fundamentals)
The following modules can be connected from an external device with the Ethernet communication.
• Ethernet interface module
• Built-in Ethernet CPU module
For Ethernet built-in CPU modules, refer to the user's manual of the CPU module used.
 MELSEC-L CPU Module User's Manual (Built-In Ethernet Function)
 QnUCPU User's Manual (Communication via Built-in Ethernet Port)
■Accessible modules via supported device
The following modules are accessible from the connected station (host station) or other station.
• CPU module
• MELSECNET/H remote I/O station
• CC-Link IE Field Network head module
• Intelligent function module
■Modules that can be relayed between networks
The networks that can be relayed by setting the network No. and station No., and the devices that can be relayed are shown
below.
Network
Module type
CC-Link IE Field Network
CC-Link IE Field Network master/local-
equipped module
CC-Link IE Field Network master/local
module
CC-Link IE Controller Network
CC-Link IE Controller Network-equipped
module
CC-Link IE Controller Network module
MELSECNET/H
MELSECNET/H module
Ethernet
Ethernet interface module
In the circumstances that multiple network modules with the same network No. are mounted on the station with C24/E71, the
access to other stations is performed via the network module mounted on the slot that has the lowest base unit number when
the network No. is specified.
The following networks are accessible.
• Ethernet (Setting the network No. and station No. are required.)
• CC-Link IE Controller Network
• CC-Link IE Field Network
• MELSECNET/H
Up to 8 connection targets (relay stations: 7 stations) can be accessed.
Model name
RJ71GF11-T2, RJ71EN71 (when using the CC-Link IE Field Network function)
LJ71GF11-T2, QJ71GF11-T2, QS0J71GF11-T2
RJ71GP21-SX
QJ71GP21-SX, QJ71GP21S-SX
QJ71LP21, QJ71LP21-25, QJ71LP21S-25, QJ71LP21G, QJ71BR11,
QJ71NT11B
RJ71EN71, LJ71E71-100, QJ71E71-100, QJ71E71-B5, QJ71E71-B2, QJ71E71
2 SUPPORTED DEVICES AND ACCESSIBLE RANGES
2.2 Accessible Range and Accessible Modules
2
21

Advertisement

Table of Contents