Commands for 4C/3C/4E/3E frame

The following shows the commands for 4C/3C/4E/3E frame.
For 4C/3C/4E/3E frame, specify subcommands in the request message as well.
Device access
Function
Batch read
Batch read in
and write
word units
Batch read in
bit units
Batch write in
word units
Batch write in
bit units
Random read
Random read
and write
in word units
Random write
in word units
(test)
Random write
in bit units
(test)
Batch read
Batch read
and write
multiple blocks
multiple
blocks
Batch write
multiple blocks
Monitor
Register
device
monitor data
memory
Monitor
Command
Description
0401
Read values from devices in word units.
Read the values in batch with specifying the consecutive device points.
Read values from devices in bit units.
Read the values in batch with specifying the consecutive device points.
1401
Write values to devices in word units.
Write the consecutive devices in batch with specifying the consecutive device
points.
Write values to devices in bit units.
Write the consecutive devices in batch with specifying the consecutive device
points.
0403
Read values from devices in word or double-word units.
Read device values with specifying device numbers.
Discontinuous device numbers can be specified.
Read values randomly in word units by specifying the monitor condition.
The read timing can be changed.
1402
Write values to devices in word or double-word units.
Write device values with specifying device numbers.
Discontinuous device numbers can be specified.
Write values to devices in bit units.
Write device values with specifying device numbers.
Discontinuous device numbers can be specified.
0406
Read values for specified multiple blocks by handling consecutive word devices
or bit devices as one block.
Each block can be specified with discontinuous device numbers.
1406
Write values for specified multiple blocks by handling consecutive word devices
or bit devices as one block.
Each block can be specified with discontinuous device numbers.
0801
Register the devices to be monitored.
Perform monitor data registration by specifying monitor conditions.
The read timing can be changed.
0802
Read the values of registered devices.
Subcommand
0000
For MELSEC-
0080
Q/L series
0002
For MELSEC
0082
iQ-R series
0001
For MELSEC-
0081
Q/L series
0003
For MELSEC
0083
iQ-R series
0000
For MELSEC-
0080
Q/L series
0002
For MELSEC
0082
iQ-R series
0001
For MELSEC-
0081
Q/L series
0003
For MELSEC
0083
iQ-R series
0000
For MELSEC-
0080
Q/L series
0002
For MELSEC
0082
iQ-R series
0040
Monitor
00C0
condition
specified
0000
For MELSEC-
0080
Q/L series
0002
For MELSEC
0082
iQ-R series
0001
For MELSEC-
0081
Q/L series
0003
For MELSEC
0083
iQ-R series
0000
For MELSEC-
0080
Q/L series
0002
For MELSEC
0082
iQ-R series
0000
For MELSEC-
0080
Q/L series
0002
For MELSEC
0082
iQ-R series
0000
For MELSEC-
0080
Q/L series
0002
For MELSEC
0082
iQ-R series
0040
Monitor
00C0
condition
specified
0000
7 COMMANDS AND FUNCTIONS
7.1 Command List
7
63

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsecq seriesMelsec l series