Mitsubishi Electric MELSEC IQ-R series Reference Manual page 56

Programmable controller
Hide thumbs Also See for MELSEC IQ-R series:
Table of Contents

Advertisement

Setting method
■Data communication in ASCII code
Convert the numerical value to 2-digit ASCII code (hexadecimal), and send it from the upper digits.
■Data communication in binary code
Send a 1-byte numerical value.
Ex.
Accessing connected station (host station) or multidrop connection station
ASCII code
Network
PC
No.
No.
0
0
F
F
30
30
46
46
H
H
H
H
When accessing other station of which network No. is '2' and station No. is '3'
ASCII code
Network
PC
No.
No.
0
2
0
3
30
32
30
33
H
H
H
H
The network No. and station No. of the network module can be checked by using the following parameters of
Engineering tool.
• GX Works2: "Network Parameter"
• GX Works3: "Module Parameter"
The network No. and the station No. of the network module are normally set in decimal. However, the network
No. and the PC No. are set in hexadecimal.
6 ACCESS ROUTE SETTINGS
54
6.2 Details of Setting Data
Binary code
Network
PC
No.
No.
00
FF
H
H
Binary code
Network
PC
No.
No.
02
03
H
H