Mitsubishi Electric MELSEC IQ-R series Reference Manual page 269

Programmable controller
Hide thumbs Also See for MELSEC IQ-R series:
Table of Contents

Advertisement

CPU error monitoring, CPU status information
Specify whether to perform error monitoring for the host station CPU module.
CPU error monitoring
Do not perform error monitoring for the host
station CPU module.
Perform error monitoring for the host station CPU
module.
When the error monitoring is performed, the CPU monitoring result is stored in the response data as a CPU status
information.
The following values are stored in the CPU status information.
Specified value
CPU status
0000H
During normal operation
0001H
Module warning occurring
0002H
Module error/module system error occurring
■Data communication in ASCII code
Convert the numerical value to 4-digit ASCII code (hexadecimal) and store it in the 'Device Data' in the following format from
upper digits.
0
1
0
0
0
0
0
30
31
30
30
30
30
30
30
H
H
H
H
H
H
H
■Data communication in binary code
Store the 2-byte numerical values in the 'Device Data' in the following format from lower byte (L: bits 0 to 7).
Device data
01
00
00
00
01
00
H
H
H
H
H
H
Monitoring condition
When 'fixed cycle send' is specified with the programmable controller CPU monitoring function, specify '0'.
ASCII code
0
0
0
0
30
30
30
30
H
H
H
H
When 'condition match send' is specified with the Programmable controller CPU monitoring function, specify the value below.
The timing to send the result can be selected.
• Edge trigger transmission: Send the result when the condition matches.
• Level trigger transmission: Send the result in the cycle time interval during the condition matches
Edge trigger
Level trigger
transmission
transmission
0001H
0101H
0002H
0102H
ASCII code
0
0
30
30
H
H
0
1
30
31
H
H
0
0
0
0
1
Device data
30
30
30
31
H
H
H
H
H
Binary code
00
00
H
H
Monitoring condition
ON/OFF status of device = ON/OFF status of monitoring
condition
Device value = Monitoring condition value
ON/OFF status of device  ON/OFF status of monitoring
condition
Device value  Monitoring condition value
13 SERIAL COMMUNICATION MODULE DEDICATED COMMANDS
Binary code
00
H
01
H
13.5 Programmable controller CPU monitoring function
Device type that can be
specified
Bit device
Word device
Bit device
Word device
267
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsecq seriesMelsec l series