wsm M6040 Workshop Manual page 95

Table of Contents

Advertisement

M6040, M7040, WSM
Cylinder Safety Valve Setting Pressure Adaptor
Application
• Use to adapt the safety valve to the nozzle tester to measure cracking pressure and test the check valve on the
safety valves.
NOTE
• The following special tools are not provided, so make them referring to the figure.
A
45 mm (1.77 in.)
B
40 mm (1.58 in.)
C
35 mm (13.8 in.)
D
23 to 23.3 mm (0.9055 to 0.9713 in.)
E
16 mm (0.63 in.)
F
40 mm dia. (1.58 in. dia.)
G
32.4 to 32.7 mm dia. (1.2756 to 1.2874 in. dia.)
H
21 mm dia. (0.83 in. dia.)
I
20 to 20.05 mm dia. (0.7874 to 0.7894 in. dia.)
J
2.5 to 2.59 mm (0.0984 to 0.1097 in.)
K
0.79 rad (45 °)
L
0.26 rad (15 °)
M
M12 × P1.5
N
10 mm dia. (0.39 in. dia.)
O
7.5 mm dia. (0.3 in. dia.)
P
1.05 rad (60 °)
Q
3 mm dia. (1.18 in. dia.)
R
36 mm (1.18 in.)
S
60 mm (2.36 in.)
T
5 mm (0.20 in.)
U
10 mm (0.39 in.)
V
M30 × P1.5
W
0.52 rad (30 °)
X
8 mm dia. (0.32 in. dia.)
Y
19 mm (0.75 in.)
Z
10 mm (0.39 in.)
G-74
GENERAL
9Y1210143GEG0107US0
KiSC issued 07, 2012 A