SECTIOn 7 |
models
oPerAting moDeS
off-line mode
on-line mode
internAl bAttery chArger Section
Ac input voltage range
max continuous Ac input current
Ac input Power factor
Programmable Dc output charg-
ing current
charger efficiency
charging Stages
battery temperature compensa-
tion
eXternAl bAttery chArger Section (Solar charge controller)
charging voltage range
maximum charging current
cooling, ProtectionS AnD AlArmS
cooling
Protections and Alarms
oPtionAl remote control
model no.
Specifications
Specifications
evo-2212
grid/generator Priority (Default)
• Grid/Generator supplies AC loads and charges batteries
• Inverter is standby
battery / inverter Priority (Programmable)
•
Inverter supplies AC loads even if Grid/Generator is available
•
Grid/Generator takes over when batteries are discharged to "battery
Low Alarm" to charge batteries and to power AC loads. AC loads are
transferred back to Inverter under various programmed conditions
15A, AC
0-100A, DC
normal mode: 3 Stages – bulk, Absorption and float
equalization mode: 4 Stages – bulk, Absorption, Equalization and float
Adaptive Charging Control
battery Temperature Sensor included
Compensation range from -20° C to 60° C
13-15VDC
Shut Down under Input Over Current, Output Over Current, Output Over-
Advanced features for programming various parameters and modes of
operation
2 rows of 16 Character Alpha Numeric LCD Display for messaging
up to 16 Gb SD Card Slot for Data Logging
Comes with 10M / 33ft rJ-45 Data Cable
evo-3012
120 VAC (60 to 140 VAC +/-5% )
20A, AC
0 - 130A, DC
75%
13-15VDC
2 fans – Temperature Controlled, Variable Speed
battery Low Voltage Alarm and Low / Over Voltage Shut Down
load and Output Short
Transformer and heat Sink Overheat Shut Down
Immunity Against Conducted Electrical Transients in Vehicles
EVO-rC (see Appendix A)
evo-2224
19A, AC
> 0.95
0 - 70A, DC
86%
26-30VDC
50A
SAMLEX AMErICA INC. | 91
evo-4024
30A, AC
0 - 110A, DC
85%
26-30VDC