SECTIOn 6 |
tAble 6.6 ProgrAmmAble AnD DefAult PArAmeterS - grouP "other functionS" (continued)
Parameter name
"comm iD"
(Communication ID for
optional remote Control
EVO-rC)
"buZZer"
"DiSchArge beeP"
(beeping in "Discharg-
ing / Inverter Mode")
"DefAult reSet"
DAtA log time
(for Optional remote
Control EVO-rC)
PArAmeter SAve
(for Optional remote
Control EVO-rC)
6.5 ProtectionS, fAult meSSAgeS AnD troubleShooting guiDe
The front panel of the unit has a red LED marked "fAuLT" (13, fig 2.1). This LED will light
up (steady) when the unit registers any of the fAult moDe situations shown in Table 7.1 of
EVO-rC Manual at Appendix A.
Table 7.1 of EVO-rC Manual at Appendix A shows details of protections and associated fault/
Error Messages that will be displayed on the LCD screen of the optional remote Control EVO-rC.
note: If the optional remote Control EVO-rC (see Appendix A) is not used, it may be
difficult to narrow down the probable cause of the fault.
6.6 Powering off the unit in fAult moDe
If the unit is in "fault Mode", it will be possible to power Off the unit with the ON/Off Push
button.
(As explained under paragraph 6.1.2, as long as AC input voltage > 60VAC is present, the
unit CANNOT bE POWErED Off using the ON / Off button on the front panel of the unit or
on the optional remote Control EVO-rC (see Appendix A). In order to power off using the
Power ON/Off button, switch Off the AC input first).
Operation, Protections and Troubleshooting
Setting range
EVO-
EVO-
2212
3012
1 - 255
0 = Off ; 1 = ON
0 = Off ; 1 = ON
0 = No ; 1 = yES
0 = Disable
3 = 30 sec
1 = 1 sec
4 = 60 sec
2 = 10 sec
5 = 5 min
0 = No
1 = yes
EVO-
EVO-
EVO-
2224
4024
2212
6 = 10 min
1
1
Default value
EVO-
EVO-
3012
2224
1
1 = On
0 = Off
0 = No
1 = 1 sec
0 = No
SAMLEX AMErICA INC. | 87