Samlexpower Evolution EVO-2212 Owner's Manual page 110

Inverter/charger pure sine wave
Hide thumbs Also See for Evolution EVO-2212:
Table of Contents

Advertisement

SECtION 4 |
4.4 GRoUP 1 PARAMeteR Set UP: cHARGe cURVe
Please refer to Parameters under Group 1 at Fig 4.1. Details of Parameter set up are given below:
tABLe 4.4. GRoUP 1 PARAMeteR Set UP: cHARGe cURVe
Page
no. for
Group
Parameter
1 (Fig
4.1)
"BULK cURRent"
1
(Bulk Charge Current
"Io")
"ABSoRP VoLtAGe"
2
(Absorption Voltage)
3
"eQUALiZe VoLtAGe"
(Equalization Voltage)
4
"FLoAtinG VoLtAGe"
(Float Voltage)
"coMPenSAte"
5
(Temperature
Compensation)
6
"BAtt oVeR VoLt"
(Battery Over Voltage
Shut Down)
7
"ReSet VoLtAGe"
("Battery Low
Voltage!") Reset
8
"LoW VoLt ALARM"
(Battery Low Voltage
Alarm)
"BAtt LoW VoLtAGe"
9
(Battery Low Voltage
Shut Down)
"LV Detect tiMe"
10
(Detect Time to
Qualify as "Battery
Low Voltage" Shut
Down Condition)
"LV cUt oFF tiMe"
11
(Time in pre Low Volt-
age Shut Down Condi-
tion (No AC output)
before complete shut
down is activated)
18 | SAMLEX AMERICA INC.
Parameter Setup
Programming Range
eVo-
2212
0 – 100A 0 – 130A
13.5V – 16.0V
14.0V – 16.0V
13.0V – 15.0V
-3mV to -5mV /°C/Cell
14.0V – 17.0V
12.0V – 17.0V
9.5V – 12.5V
9.1V – 12.0V
eVo-
eVo-
eVo-
3012
2224
4024
0 – 70A
0 – 110A
27.0V – 32.0V
28.0V – 32.0V
26.0V – 30.0V
28.0V – 35.0V
24.0V – 35.0V
19.0V – 25.0V
18.1V – 24.0V
0-600 sec
0-7200 sec
APPENDIX A
Default
eVo-
eVo-
eVo-
2212
3012
2224
40A
14.4V
28.8V
14.4V
28.8V
13.5V
27.0V
-4mV /°C/Cell
16.0V
32.0V
14.0V
28.0V
11.0V
22.0V
10.5V
21.0V
10 sec
1200 sec
eVo-
4024

Hide quick links:

Advertisement

Table of Contents
loading