SECtION 4 |
programmed level of voltage = "RESET VOLTAGE" [(i) for 12V: 12.0V – 17.0V / Default
14.0V (ii) for 24V: 24.0V – 35.0V / Default 28.0V], or higher before the Transfer Relay is
switched OFF (de-energized) to exit "Charging" Mode and revert to "Inverting" Mode .
Enter Key
SELECT GROUP
CHARGE CURVE
4.5 GRoUP 2 PARAMeteR Set UP: inPUt SettinG
Please refer to Parameters under Group 2 at Fig 4.1. Details of Parameter set up are given below:
tABLe 4.5. GRoUP 2 PARAMeteR Set UP: inPUt SettinG
Page
no. for
Group
Parameter
2 (Fig
4.1)
1
DeFAULt FReQ
2
GRiD MAX cURRent
3
Gen MAX cURRent
4
HiGH cUt oFF
5
HiGH ReSet
6
LoW cUt oFF
7
LoW ReSet
DeFAULt FReQ:
Default frequency sets the Inverter frequency, which is also the standard frequency for AC input.
Up Key
SELECT GROUP
CHARGE CURVE
GRiD MAX cURRent / Gen MAX cURRent:
In Charging Mode, the net AC input current from the Grid/Generator is the sum of the AC
side charging current and the pass through load current. Based on the rated capacity of the
Grid Branch Circuit/Generator, the net AC input current will be required to be limited to
prevent overloading of the Grid Branch Circuit/Generator.
EVO Series has a very powerful battery charger that will require a proportionate higher
AC input current from the Grid/Generator. The Grid/Branch Circuit/Generator will also be
required to provide current to the AC loads. The desired maximum value of input current
from Grid/Generator can be programmed (Default is 30A). The EVO will automatically reduce
charging current to support the AC loads on priority and use whatever is extra for charging.
This will prevent overloading of the Grid Branch Circuit/Generator. If the AC input current is
over the setting value by 1A for 5 seconds, the EVO Inverter Charger will stop outputting and
display an error message "Input over current!" on LCD screen.
26 | SAMLEX AMERICA INC.
Parameter Setup
Up Key x 17
CHARGE CURVE
BULK CURRENT
eVo-
2212
0 = 60Hz; 1 = 50Hz
5 – 40A 5 – 70A 5 – 40A
5 – 40A 5 – 70A 5 – 40A
Enter Key
SELECT GROUP
INPUT SETTING
GEN OFF TIME
60 min
Setting range
eVo-
eVo-
eVo-
3012
2224
4024
5 – 70A
5 – 70A
50 – 70Hz
50 – 70Hz
40 – 60Hz
40 – 60Hz
DEFAUT FREQ
0= 60Hz
APPENDIX A
Default value
eVo-
eVo-
eVo-
2212
3012
2224
0 = 60Hz
30A
30A
65Hz
64Hz
55Hz
56Hz
eVo-
4024