SECtION 4 |
4.8 GRoUP 5 PARAMeteR Set UP: otHeR FUnctionS
Please refer to Parameters under Group 5 at Fig 4.2. Details of Parameter set up are given below:
tABLe 4.8. GRoUP 5 PARAMeteR Set UP: otHeR FUnctionS
Page
no. for
Parameter
Group 5
(Fig 4.2)
1
PoWeR SAVinG
2
enteR Point
3
WAKe UP Point
4
ReMote SWitcH
5
ReLAY FUnction
6
coMM iD
7
BUZZeR
8
DiScHARGe BeeP
9
DeFAULt ReSet
DAtALoG DiSABLe
10
DAtALoG tiMe
11
PARAMeteR SAVe
PoWeR SAVinG:
Enable or disable Power Saving Mode when in "Inverting Mode".
Up Key x 4
SELECT GROUP
CHARGE CURVE
enteR Point:
If the value of power drawn by AC load falls to the "ENTER POINT" value for 5 sec, the unit
will enter "Power Save Mode".
Up Key x 4
SELECT GROUP
CHARGE CURVE
Parameter Setup
eVo-
2212
1 = Enable
0 = Disable, 1 = 1 sec,
2 = 10 sec, 3 = 30 sec
4 = 1 min, 5 = 5 min, 6 = 10 min
Enter Key
SELECT GROUP
OTHER FUNCTION
Enter Key
SELECT GROUP
OTHER FUNCTION
Setting range
eVo-
eVo-
eVo-
3012
2224
4024
0 = Disable
4 – 50W
5 – 50W
0 = Button Type
1 = Switch Type
0 = Charge/Other
1 = Normal/Fault
2 = Generator 0
3 = Generator 1
4 = Generator 2
1 – 255
1 = ON
0 = OFF
1 = ON
0 = OFF
0 = No
1 = Yes
0 = No
1 = Yes
POWER SAVING
1 = Enable
POWER SAVING
1 = Enable
APPENDIX A
Default value
eVo-
eVo-
2212
3012
1 = Enable
6W
8W
7W
10W
Button type
2 = Generator 0
1
1 = ON
0 = OFF
0 = No
1 = 1 sec
0 = No
Up Key x 1
ENTER POINT
6W / 8W
SAMLEX AMERICA INC. | 31
eVo-
eVo-
2224
4024
6W
8W
7W
10W