Samlexpower Evolution EVO-2212 Owner's Manual page 67

Inverter/charger pure sine wave
Hide thumbs Also See for Evolution EVO-2212:
Table of Contents

Advertisement

SECTIOn 4 |
legend for fig 4.1(a)
K2
Transfer relay (40A) for Grid, Line
K3
Transfer relay (40A) for Generator, Line
K4
relay (40A) for Neutral to Ground bond Switching
4, 3
Normally Closed Contacts
4, 5
Normally Open Contacts
QD
Quick Disconnect (13, fig 3.9) for disconnecting Output Neutral to Chassis Ground bond in
Inverting Mode (Default - connected)
NOTE:
relays are de-energized in Inverting Mode and are energized in Charging Mode
NEUTRAL
INVERTING
CHARGING
BI-DIRECTIONAL
TRANSFORMER
LINE
fig 4.1(b) operation of transfer relay and neutral to ground bond Switching in evo-3012 and evo-4024
legend for fig 4.1(b)
K2
DPDT Transfer relay (70A) for Grid, Line
K3
DPDT Transfer relay (70A) for Generator, Line
K4
DPDT Transfer relay (70A) for Neutral to Ground bond Switching
7,1 and 9,3
Normally Closed Contacts
7,4 and 9,6
Normally Open Contacts
QD
Quick Disconnect (13, fig 3.9) for disconnecting Output Neutral to Chassis Ground
bond in Inverting Mode (Default - connected)
NOTE:
relays are de-energized in Invertering Mode and are energized in Charging Mode
general Description & Principles of Operations
K4
1
4
7
3
6
9
K2
1
4
7
3
6
9
K3
1
4
7
3
6
9
Two 35A each poles are paralleled for 70A capacity
Two 35A each poles are paralleled for 70A capacity
Two 35A each poles are paralleled for 70A capacity
QD
METAL CHASSIS
GROUND OF THE UNIT
GEN
AC OUTPUT
GRID
GEN
LINE
LINE
LINE
GND
OUTPUT
GRID
GEN
GND
GND
NEUTRAL
NEUTRAL
SAMLEX AMErICA INC. | 67
OUTPUT
GRID
NEUTRAL