SECtION 4 |
"NO" contacts of the Status Relay will open to initiate automatic stopping of the
Generator. When AC output from the Generator switches OFF, EVO will change over to
"Inverting Mode" (NOTE: The State of Charge of the battery after the Status Relay has
been switched OFF (de-energized) and Generator is stopped will be indeterminate).
Diagram showing steps for programming the above RELAY FUNCTION is given below:
Up Key x 4
SELECT GROUP
CHARGE CURVE
coMM iD:
Communication ID- This sets the ID number for the COMM Port and EVO-RC Remote Control.
Up Key x 4
SELECT GROUP
CHARGE CURVE
BUZZeR:
Set the buzzer ON/OFF.
Up Key x 4
SELECT GROUP
CHARGE CURVE
DiScHARGe BeeP:
To select the buzzer ON/OFF while in "Inverting Mode".
Up Key x 4
SELECT GROUP
CHARGE CURVE
DeFAULt ReSet
This is to reset all of the parameters to the Default Values.
Up Key x 4
SELECT GROUP
CHARGE CURVE
DAtALoG tiMe AnD DAtALoG DiSABLe:
Set the time period of the data log.
0 = Disable
4 = 60 sec
Up Key x 4
SELECT GROUP
CHARGE CURVE
36 | SAMLEX AMERICA INC.
Parameter Setup
Enter Key
SELECT GROUP
OTHER FUNCTION
Enter Key
SELECT GROUP
OTHER FUNCTION
Enter Key
SELECT GROUP
OTHER FUNCTION
Enter Key
SELECT GROUP
OTHER FUNCTION
Enter Key
SELECT GROUP
OTHER FUNCTION
1 = 1 sec
5 = 5 min
Enter Key
SELECT GROUP
OTHER FUNCTION
Up Key x 4
POWER SAVING
1 = Enable
Up Key x 5
POWER SAVING
1 = Enable
Up Key x 6
POWER SAVING
1 = Enable
Up Key x 7
POWER SAVING
1 = Enable
Up Key x 8
POWER SAVING
1 = Enable
2 = 10 sec
6 = 10 min
Up Key x 9
POWER SAVING
1 = Enable
APPENDIX A
RELAY FUNCTION
2 = Generator 0
COMM. ID
1
BUZZER
1 = ON
DISCHARGE BEEP
0 = OFF
DEFAULT RESET
0 = No
3 = 30 sec
DATALOG TIME
1 = 1 sec

Hide quick links:

Advertisement

Table of Contents
loading