SECTIOn 6 |
6.7 12v, 100mA cAPAcity Dc Source for SignAling
A 12V, 100mA capacity DC source has been provided (16, fig 2.1). This voltage may be
routed through the contacts of the Status relay (14, fig 2.1) to feed 12V ON / Off control
signal to drive circuits of remote monitoring control of the programmable conditions of
operation of the unit (refer to Table 6.6 under relay function).
6.8 StAnDby moDe
This Mode is required to be switched ON manually during firmware uploading procedure
for EVO Inverter Charger. firmware upload is carried out through the SD Card slot provided
on the optional remote Control Model EVO-rC [9, fig 2.4(a)]. When firmware uploading
procedure is initiated, the user will be prompted to switch ON Standby Mode – message on
the LCD screen on the EVO-rC will show "Press power key to stop inverter". Once firmware
upload is completed, the EVO exits the Standby Mode automatically. Please refer to Section
3.4 of the EVO-rC remote Control Owner's Manual at Appendix A.
note: Standby Mode may also be used to temporary halt normal operation of the Inverter
Charger without switching Off the unit completely.
for the Standby Mode to be switched ON, the EVO should be in ON condition and should be
operating in one of the 3 Operating Modes – "Inverting" or "Charging" or "Power Saving"
(See fig 3.1 of the EVO-rC Owner's Manual at Appendix A). When Standby Mode is switched
ON, the EVO will exit its Operating Mode.
Standby Mode is toggled between ON and Off conditions as follows:
by momentary pressing (0.1 sec) of ON/Off Push button on the front panel of the unit
(11, fig 2.1)
by momentary pressing (0.1 sec) of ON/Off Push Key on the optional remote Control
EVO-rC [2, fig 2.4(a)]
When the EVO is in "Standby Mode", operational status will be displayed as follows:
on the front panel of evo:
-
No LED display. Green LED marked "ON" (12, fig 2.1) and red LED marked "fAuLT"
(13, fig 2.1) will both be Off.
-
No buzzer
on the remote control evo-rc:
-
No LED display. Green LED marked "Status" (3, fig 2.4a) and red LED marked
"fAuLT" (4, fig 2.4a) will both be off
-
The LCD will display
Appendix A)
-
No buzzer
88 | SAMLEX AMErICA INC.
Operation, Protections and Troubleshooting
STANDBY
BATTERY
(fig 3.1 in the EVO-rC Owner's Manual at
XX.XXV