SECtION 4 |
cUt oFF VoLt 1:
If during "Charging Mode", the AC input voltage rises above "CUT-OFF VOLT 1" for period >
"DETECT TIME 1", the EVO Inverter Charger will transfer to "Inverting Mode".
Up Key x 3
SELECT GROUP
CHARGE CURVE
Detect tiMe 1:
This is the time limit in cycles up to which high AC input voltage "CUT-OFF VOLT 1" is allowed.
Up Key x 3
SELECT GROUP
CHARGE CURVE
cUt oFF VoLt 2:
If during "Charging Mode", the AC input voltage rises above "CUT-OFF VOLT 2" for period >
"DETECT TIME 2", the EVO Inverter Charger will transfer to "Inverting Mode".
Up Key x 3
SELECT GROUP
CHARGE CURVE
Detect tiMe 2:
This is the time limit in cycles up to which high AC input voltage "CUT-OFF VOLT 2" is allowed.
Up Key x 3
SELECT GROUP
CHARGE CURVE
cUt oFF VoLt 3:
If during "Charging Mode", the AC input voltage rises above "CUT-OFF VOLT 3" for period >
"DETECT TIME 3", the EVO Inverter Charger will transfer to "Inverting Mode".
Up Key x 3
SELECT GROUP
CHARGE CURVE
Detect tiMe 3:
This is the time limit in cycles up to which high AC input voltage "CUT-OFF VOLT 3" is allowed.
Up Key x 3
SELECT GROUP
CHARGE CURVE
30 | SAMLEX AMERICA INC.
Parameter Setup
Enter Key
SELECT GROUP
INPUT HIGH LIMIT
Enter Key
SELECT GROUP
INPUT HIGH LIMIT
Enter Key
SELECT GROUP
INPUT HIGH LIMIT
Enter Key
SELECT GROUP
INPUT HIGH LIMIT
Enter Key
SELECT GROUP
INPUT HIGH LIMIT
Enter Key
SELECT GROUP
INPUT HIGH LIMIT
Up Key x 1
RESET VOLTAGE
135.0 V
Up Key x 2
RESET VOLTAGE
135.0 V
Up Key x 3
RESET VOLTAGE
135.0 V
Up Key x 4
RESET VOLTAGE
135.0 V
Up Key x 5
RESET VOLTAGE
135.0 V
Up Key x 6
RESET VOLTAGE
135.0 V
APPENDIX A
CUT OFF VOLT 1
140.0 V
DETECT TIME 1
60 cycle
CUT OFF VOLT 2
145.0 V
DETECT TIME 2
15 cycle
CUT OFF VOLT 3
150.0 V
DETECT TIME 3
1 cycle