Samlexpower Evolution EVO-2212 Owner's Manual page 100

Inverter/charger pure sine wave
Hide thumbs Also See for Evolution EVO-2212:
Table of Contents

Advertisement

SECtION 3 |
For the Standby Mode to be switched ON, the EVO should be in ON condition and should be
operating in one of the 3 Operating Modes – "Inverting" or "Charging" or "Power Saving"
(See Fig 3.1 of the EVO-RC Owner's Manual at Appendix A). When Standby Mode is switched
ON, the EVO will exit its Operating Mode.
Standby Mode is toggled between ON and OFF conditions as follows:
By momentary pressing (0.1 sec) of ON/OFF Push Key [2, Fig 2.4(a)], OR
By momentary pressing (0.1 sec) of ON/OFF Push Button on the front panel of the unit (11,
Fig 2.1 in the Owner's Manual for Evolution Series Inverter Charger)
When the EVO is in "Standby Mode", operational status will be displayed as follows:
on the Remote control eVo-Rc:
-
No LED display. Green LED marked "Status" (3, Fig 2.4a) and Red LED marked
"FAULT" (4, Fig 2.4a) will both be off
-
The LCD will display
Appendix A)
-
No buzzer
on the front panel of eVo:
-
No LED display. Green LED marked "ON" (12, Fig 2.1 in the Owner's Manual for
Evolution Series Inverter Charger ) and Red LED marked "FAULT" (13, Fig 2.1 in the
Owner's Manual for Evolution Series Inverter Charger ) will both be OFF.
-
No buzzer
3.5. FAULt cLeARinG
If any fault occurs, the LCD screen will display the Fault Message, Red LED Alarm (Fault) will be lighted.
Remove cause of the fault and the unit will remain in Fault Mode. A short press (0.1 seconds) of the
on/oFF button will clear the Fault Message and the EVO Inverter Charger will return to operational
status (if the fault condition no longer exists). Refer to section 7 on "Fault Messages".
3.6 oPeRAtinG MoDeS AnD DiSPLAY ScReenS
There are 4 Operating Modes for the EVO Inverter Charger that will be displayed on the Remote
Screen at any given time (see Fig 3.1): (i) Standby (ii) Inverting (iii) Charging and (iv) Power Saving.
Each mode has several screens of status information such as Voltage/Current/Power etc. as detailed
at Section 3.6.2 and Fig 3.2. The majority of Mode screens shown in Fig 3.1 are self explanatory, but
the Charging Mode Status screens require additional details which are shown at Section 3.6.1.
STANDBY
BATTERY XX.XXXV
8 | SAMLEX AMERICA INC.
Operation
STANDbY
bATTERY
INVERTING
OUTPUT
CHARGING
INPUT 1
Fig 3.1 eVo-Rc Mode Screens
(Fig 3.1 in the EVO-RC Owner's Manual at
XX.XXV
120.00V
N-CC
120.00V
APPENDIX A
POWER SAVING
BATTERY XX.XXXV

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents