3.6.1 charging Mode Screens explanations
Please refer to 19 Screens shown against Pages 1 to 19 under Group 3 "CHARGING" at Fig
3.2. The 1
line of the Display Screen for Charging Mode shows CHARGING on the left and
st
abbreviated information format "Charging Mode - Charging Stage" on the right corner. The
following abbreviations have been used:
Abbreviation
(Group 3 Screens)
N-CC
N-CV
E-CC
E-CVA
E-CVE
FLOAT
For example, in Fig 3.2, the 1
"N-CC" in the right corner. This means that the unit is in Normal (N), 3-Stage Charging Mode
and is in Constant Current (CC) Bulk Stage.
3.6.2 overall operating Mode Display Screen Menu Map
Overall Operating Mode Display Screen Menu Map is shown at Fig 3.2. Any screen within the
Menu Map can be identified by 2 co-ordinates: "Group No." (Column) and "Page No." (Row).
Operation
normal (n), 3 Stage charging:
Bulk, Absorption, Float
Constant Current (CC), Bulk Stage
Constant Voltage (CV), Absorption Stage –
–
–
–
Float Stage
line of information under Column 4 (Group 3) "Charging" shows
st
equalization (e), 4-Stage charging:
Bulk, Absorption, equalization, Float
–
Constant Current (CC), Bulk Stage
Constant Voltage Absorption (CVA) Stage
Constant Voltage Equalization (CVE) Stage
Float Stage