Log Printer; Ip Board (K-Net Module); Zones - Bentel Security KYO 320 Installation Manual

Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

n Log Printer
From the Configuration menu, using A or B, select Log
Printer.
Configuration

Log Printer

1. Press ENTER:
Options
Print Logger
2. Using A or B, select Print Logger option (refer
to "Real-time Printout") or Agg. Linefeed (refer to "Agg.
Linefeed"), then press ON or OFF to enable or disable
the option concerned. The last character on the bottom
line will show.
- option disabled
û option enabled
Press ENTER to confirm and go back to the Configura-
tion menu.
n IP board (K-NET module)
From the Configuration menu, using A or B, select "IP
board"
Configuration
IP board
1. Press ENTER:
IP board
Not present
2. Press ON to enrol the IP board (Present), then press
ENTER to continue. To unenrol the IP board (delete
from the Configuration), press OFF.

Zones

Press ESC to exit the Configuration menu and go back
to the PROGRAMMING menu.
PROGRAMMING
Configuration
1. Using A or B, select the Zones option, then press
ENTER.
PROGRAMMING
Zones
2. Press ENTER:
3 Zones relating to M-IN/OUT expanders programmed as Input and Output Expanders are NOT all usable, even if they
are shown on the display. For example, if Input Expander no. 1 is an M-IN/OUT Expander programmed as an
Expander with 4 Zones + 2 Outputs, Zones 073 and 074 are NOT usable. In general, Zones [67+(x*6)] and [68+(x*6)]
of M-IN/OUT Expanders programmed as Expanders with 4 Zones + 2 Outputs, and Zones [67+(x*6)], [68+(x*6)],
[69+(x*6)] and [70+(x*6)] of M-IN/OUT Expanders programmed as Expanders with 4 Outputs + 2 Zones, where "x" is
the address of the Expander, are NOT usable.
KYO320
Zones
Wired zones
Using A or B, select Wired Zones or Wireless Zones.
Zones
Wireless zones
Wired Zones
From step 2 press ENTER.
Wired Zone 001
Zone
3. Using A or B, select the wired zone to be program-
3
med
, then press ENTER.
Description
Zone
4. Enter the Zone label (refer to "Editing a text" under
"Using the Keypad"), then press ENTER.
Zona
Double balanced
5. Using A or B, select the Zone Balancing: Double Ba-
lanced, 10K Balanced, Normally Closed, Glass Bre-
ak,
Balanced
Balanced, Normally Open. Once the Balancing has
been selected, press ENTER.
+
If you select Customized, you must also assign
the Standby, Alarm, Tamper or Short-circuit sta-
tus to the Voltage range, as follows.
5a. Using keys 1 through 4, assign the status to the cor-
responding Threshold (refer to "Thresholds").
Default settings:
1 = 1% through 34%; 2 = 34% through 50%;
3 = 50% through 67%; 4 = 67% through 98%
Zone
Alarm
You must assign either the Alarm Zone attribute (for
Alarm detection), or the Command Zone attribute (for
System management) to all Zone Balancing types other
than Glass Break.
6. Using A or B, select Alarm or Command, then press
ENTER. Go to step 7a for Alarm zones, or 7d for Com-
mand zones.
PROGRAM PANEL
001
001
001
Alarm
Only,
Customized,
001
1K
21