n Log Printer
From the Con fi gu ra tion menu, using A or B, se lect Log
Prin ter.
Con fi gu ra tion

Log Printer

1. Press ENTER:
Options
Print Logger
2. Using A or B, se lect Print Log ger op tion (re fer
to "Real-time Prin to ut") or Agg. Li ne fe ed (re fer to "Agg.
Li ne fe ed"), then press ON or OFF to ena ble or di sa ble
the op tion con cer ned. The last cha rac ter on the bot tom
line will show.
- op tion di sa bled
û op tion ena bled
Press ENTER to con firm and go back to the Con fi gu ra -
tion menu.
n IP board (K-NET mo du le)
From the Con fi gu ra tion menu, using A or B, se lect "IP
bo ard"
Con fi gu ra tion
IP board
1. Press ENTER:
IP board
Not present
2. Press ON to en rol the IP board (Pre sent), then press
ENTER to con ti nue. To unen rol the IP board (de le te
from the Con fi gu ra tion), press OFF.

Zones

Press ESC to exit the Con fi gu ra tion menu and go back
to the PROGRAMMING menu.
PROGRAMMING
Con fi gu ra tion
1. Using A or B, se lect the Zo nes op tion, then press
ENTER.
PROGRAMMING
Zones
2. Press ENTER:
3 Zones relating to M-IN/OUT expanders programmed as Input and Output Expanders are NOT all usable, even if
they are shown on the display. For example, if Input Expander no. 1 is an M-IN/OUT Expander programmed as
an Expander with 4 Zones + 2 Outputs, Zones 073 and 074 are NOT usable. In general, Zones [67+(x*6)] and
[68+(x*6)] of M-IN/OUT Expanders programmed as Expanders with 4 Zones + 2 Outputs, and Zones [67+(x*6)],
[68+(x*6)], [69+(x*6)] and [70+(x*6)] of M-IN/OUT Expanders programmed as Expanders with 4 Outputs + 2
Zones, where "x" is the address of the Expander, are NOT usable.
KYO320
Zones
Wired zones
Using A or B, se lect Wi red Zo nes or Wi re less Zo nes.
Zones
Wireless zones
Wi red Zones
From step 2 press ENTER.
Wi red Zone 001
Zone
3. Using A or B, se lect the wi red zone to be pro gram -
3
med
, then press ENTER.
De scri ption
Zone
4. Enter the Zone la bel (re fer to "Edi ting a text" un der
"Using the Key pad"), then press ENTER.
Zona
Double balanced
5. Using A or B, se lect the Zone Ba lan cing: Do u ble Ba -
lan ced, 10K Ba lan ced, Nor mally Clo sed, Glass Bre -
ak,
Ba lan ced
Ba lan
ced,
been se lec ted, press ENTER.
+
If you se lect Cu sto mi zed, you must also as sign
the Standby, Alarm, Tam per or Short-cir cu it sta -
tus to the Vol ta ge ran ge, as fol lows.
5a. Using keys 1 thro ugh 4, as sign the sta tus to the cor -
re spon ding Thre shold (re fer to "Thre sholds").
De fa ult set tings:
1 = 1% thro ugh 34%; 2 = 34% thro ugh 50%;
3 = 50% thro ugh 67%; 4 = 67% thro ugh 98%
Zone
Alarm
You must as sign eit her the Alarm Zone at tri bu te (for
Alarm de tec tion), or the Com mand Zone at tri bu te (for
System ma na ge ment) to all Zone Ba lan cing types ot her
than Glass Bre ak.
6. Using A or B, se lect Alarm or Com mand, then press
ENTER. Go to step 7a for Alarm zo nes, or 7d for Com -
mand zo nes.
PROGRAM PANEL
001
001
001
Alarm
Only,
Cu sto mi zed,
Nor mally Open. Once the Ba lan cing has
001
1K
21