1PosUniversal/Digital
7.6 Functions of the 1PosU
Causes of Errors for JOB_ERR
Table 7-4
Causes of Errors for JOB_ERR
Error Number
Meaning
21
JOB unknown or impermissible
23
ERR_ENCODER is displayed
26
JOB 2 (move encoder range) cannot be initiated
because there is an active run
29
Evaluating the Reference Signal: Reference point
coordinates ≥ end of rotary axis
34
Setting an Actual Value: Actual value coordinates
≥ encoder range
35
Display current values: Selection unknown
36
Latch Function: Edge selection unknown
37
Display current values: JOB 15 cannot be
activated with the latch function running.
38
Monitoring of the direction of rotation
Path difference > 65 535
366
Remedy
Permissible JOBs are:
JOB 0
•
JOB 1
•
JOB 2 (only possible at SSI encoders)
•
JOB 3
•
JOB 4
•
JOB 9 (not possible at SSI encoders or in
•
dosing operation)
JOB 10
•
JOB 11 (not possible in dosing operation)
•
JOB 15
•
Check the encoder wiring
Operating Instructions, 05/2007, A5E00124871-04
ET 200S Positioning