1PosInc/Analog
4.8 Parameter List
4.8
Parameter List
Overview
Parameters
Enables
Group diagnostics
Encoder signal
diagnostics
Zero marker
diagnostics
Axis
Reversal of the
direction of rotation
Axis type
End of rotary axis
Digital Inputs
DI0 limit switch minus
DI1 limit switch plus
DI2 reducing cam
178
Meaning
An encoder error (ERR_ENCODER)
or parameter assignment error
results in a channel-specific
diagnostics if group diagnostics is
enabled.
Encoder signals A, /A and B, /B are
monitored for short circuit and wire
break.
Zero marker signals N, /N are
monitored for short circuit and wire
break.
Adjustment of the direction of rotation
of the encoder
Selection of linear axis without
limitation or rotary axis with
overrun/underrun at end of rotary
axis
Only relevant for rotary axis type:
Underrun: 0 to end of rotary axis - 1
Overrun: End of rotary axis - 1 to 0
Parameter assignment error at 0
Switch on the DI0 digital input is a
break or make contact
Switch on the DI1 digital input is a
break or make contact
Switch on the DI2 digital input is a
break or make contact
Value range
Disable
•
Enable
•
On
•
Off
•
On
•
Off
•
Off
•
On
•
Linear
•
Rotary
•
1 - 16 777 215
Break contact
•
Make contact
•
Break contact
•
Make contact
•
Break contact
•
Make contact
•
Operating Instructions, 05/2007, A5E00124871-04
Default setting
Disable
On
On
Off
Linear
36000
Break contact
Break contact
Make contact
ET 200S Positioning